ND 3867-1 LinkMaster PRO XL Ins
3) Connect cable to be traced to main unit. For best signal, do not connect remote.
Due to the canceling effect of twisted pairs, the strongest signal is obtained by having
one wire of a pair carry tone. Selecting a single pin instead of a pair will do this.
4) To turn tone off, press the MODE button until OFF is displayed, then the SEL button.
The tone will power off automatically after 2
Note: When using the coax adapter or alligator clip assembly, tone is connected only to Pin 1 and Pin 2
To Blink Hub
When Mode is selected, the LinkMaster
3 seconds, then no pulse for 3 seconds for an overall cycle time of 6 seconds. The TEST icon is
on when sending pulses and off when not. It turns off automatically after 1.2 hours.
BATTERY REPLACEMENT – When the "battery low" icon is on, the battery should be replaced as soon
as practical. The cable testing results will become unreliable when the battery reaches about 4.5 volts.
To replace battery:
1) Remove rubber battery cap on bottom of main unit by pulling or prying off with hand.
2) Remove and replace battery.
3) Snap battery cap back into place
Note: When installing a new battery, disconnect any cables connected.
The length and cable test modes will be improperly calibrated if a cable is present.
SPECIFICATIONS
Environmental:
Operating temperature: 0 to 50°C (32 to 122°F)
Storage temperature: -10 to 60°C (14 to 140°F)
Humidity: 10% to 90%, non-condensing
Battery Life (9V Alkaline battery, typical) Times are for the full capacity
of the battery used continuously in one of the following modes:
Standby: 3.5 years
Cable Testing: No Back Light (Tone, Length, Test) 108 hours
Back Light On (Tone, Length, Test) 27 hours
Cable Types: Shielded or unshielded, Cat 6, Cat-5E, Cat-5, Cat-4, Cat-3 and Coax
Minimum cable length for testing for split pairs: 1 meter (3 feet)
Minimum cable length for TEST: 1.25 meter (4 feet)
Length measurement range (CAT5/6): 0 to 640 meters (0 to 2100 feet)
Length measurements coax cable: Average 3,000 ft. – depends on coax cable resistance values
Applied Voltage: 100 volts DC or RMS AC applied continuously. Can stand 240 volt peak.
INTERPRETING CABLE TEST RESULTS – The PASS icon will be on if the cable has all pins
properly connected per T568A/B standard. The FAIL icon will be on if there is a short or split pair.
Neither icon will be on if there are opens or miswires. The wiremap should be inspected for these
types of errors.
Definition of Errors – (See failure example drawings) The three classes of faults below are in order
of severity. The more severe wiremap error will mask less severe wiremap errors. For example, if
there is a short in the cable; miswires and splits pairs may not be detected until the short is corrected.
Short – The pair has a low resistance connection from one wire of any pair to another wire in any pair in
the cable or shield. A short with remote attached is indicated by the FAIL icon being on and flashing X' s in
the appropriate pin position of the second display line. Error messages listing all the pins shorted together
will also be displayed. In the CABLE TEST mode (no remote), all error messages will be displayed.
2/19/04
3:51 PM
1
hours.
2
Pro XL sends link pulses on the NIC transmit pair for
(Hub Blink) 54 hours
(Hub Blink) 20 hours