Eikon
Arké
20136.120
19136.120
Dimmer 120 V~ 60 Hz for: 40-500 W incandescent lamps, 40-300 VA electronic transfomers,
10-200 W CFL lamps, 3-200 W LED lamps and LED electronic transfomers, control with built-in
push button or from NO peripheral push buttons, control and regulation by rotary potentiometer,
MASTER function, minimum power control, visible in darkness, grey. Not for Isoset enclosures.
IMPORTANT: Lamps controllable from a single MAsTER or sLAVE dimmer must all be
the same. All controllable loads must be declared DIMMERABLE by the manufacturer.
Check the type of compatible dimmering on the lamp package: LE (Leading Edge) or TE
(Trailing Edge). Where not specified, the lamp works in both modes, at the discretion of
the installer; choose the type of dimmering that ensures the best lamp.
Dimmering with Leading Edge mode
ChARACTERIsTICs
• Turning on and turning off is with the built-in button or normal buttons without pilot light when
off; knob dimmering.
• Soft start: ensures gradual lighting from zero to maximum or preset lighting levels. This way the
life of a lamp is increased by reducing stress on the filament and prevents light flash.
• Flash start: used with compact fluorescent lamps, ensures that the lamps are switched on
correctly, reducing any difficulties to a minimum.
• Soft end: slowly brings the load down from on to off.
• Leading Edge mode: used with incandescent lamps, compact fluorescent lamps and LED
compatible lamps, as well as L-type electronic transformers
• Tailing Edge mode: used with compatible loads such as fluorescent lamps, LED lamps or
.
C-type electronic transformers
C
• Protection against short-circuit when turning on together with flashing blowout detector.
• Overheating protection with flashing blowout detector.
• MASTER-SLAVE function: paying attention not to exceed maximum power controllable by
each dimmer. A MASTER device can have up to 3 SLAVE devices for a maximum total load
of 2000 W (VA) corresponding to 500 W/VA max connected to each of the 4 devices. When
used with fluorescent or LED lamps, the maximum power controlled from the master must
not exceed 40 W.
• It should be used in dry, dust-free places at a temperature between 0 °C and +35 °C.
• For installations with 2 dimmers in the same box the loads controllable by each dimmer should
be reduced so that their total does not exceed the values indicated above.
CONNECTIONs
• The connection should be made together with a fuse box with quick-acting fuse with high
breaking capacity type F5AH 250 V~.
• Control with built-in button or more points with NO buttons in parallel. Do not use NO buttons
with pilot light.
NOTE: ThE ON/OFF BuTTON Is CONNECTED TO ThE CABLE NEuTRAL.
• In the 2-wire connection of the adapter load must be positioned as close as possible to the
lamp and connected in parallel to it.
• For correct operation, the length of each connection between the MASTER and SLAVE dim-
mers or the NO buttons may not exceed 100 m.
• Press the connection conductors to the bottom of the box to prevent them from coming into
contact with the dimmer body.
Viale Vicenza, 14 - I 36063 Marostica VI
Tel. +39 0424 488 600 - Fax (Italia) +39 0424 488 188 - Fax (Export) +39 0424 488 709
www.vimar.com
Idea
Plana
16603.120
14136.120
Dimmering with Trailing Edge mode
.
L
3-WIRE CONNECTION
L
20136.120-19136.120
16603.120-14136.120
20416
P
19416
16460
14416
L
Button ON/OFF
and dimmering
N
Controllable loads
40 ÷ 500 W
10 ÷ 100 W (max 5 lamps)
3 ÷ 100 W (max 5 lamps)
Electronic transformers
40 ÷ 300 W
for halogen
(max 3 transformers
Power supplies
max 10 power supplies
01874.120-01875.120
Lamps 02662.120
max 10 lamps
2-WIRE CONNECTION
L
20136.120-19136.120
16603.120-14136.120
20416
19416
16460
14416
L
P
Button ON/OFF
and dimmering
N
In this configuration, it is always necessary to use the adapter to load art. 01873.120
Controllable loads
+ 01873.120
10 ÷ 40 W (max 2 lamps)
+ 01873.120
3 ÷ 40 W (max 2 lamps)
sETTINg
Remove the upper button.
N
LE
TE
40 ÷ 300 W
10 ÷ 200 W (max 10 lamps)
3 ÷ 200 W (max 10 lamps)
40 ÷ 300 W
)
(max 5 transformers
L
Not applicable
Not applicable
The 2-wire connec-
tion
be used to replace
01873.120
regulators in existing
electrical
where it is not 'this
the neutral wire in the
120 V~ 60 Hz
box of the dimmer.
S
N
LE
TE
10 ÷ 40 W (max 2 lamps)
3 ÷ 40 W (max 2 lamps)
Increases the
minimum
Decreases the
minimum
Flash start
TE
switch on for max. 1
second then taken to the
set brightness
LE
Soft start
gradually switched on to the
set brightness
)
C
should
only
systems