Click
2
NOTE: At this point, you could install the DirectChill™ unit
(WHAF-0115AG) and/or the DirectHot™ unit with dual faucet
(WHAF-0155AF) sold separately. Please refer to the Use and Care
Guides for those specific products.
If you do not install these options, please follow the next steps.
Install the faucet
See the "Location requirements" and the "Water supply
requirements" section prior to starting the faucet installation.
NOTE: If your existing faucet has a removable sprayer and you
would like to install your new UltraEase™ faucet in the sprayer
hole, start the installation at step 9. If not, start at step 14.
10
14. If you install filterhead valve C,
repeat steps 2 to 7. If you do
not install filterhead valve C
1
(WHAF-0435AC), go to "Install
the faucet" section.
1. Turn off both hot and cold
water supply to your faucet.
Disconnect sprayer hose from
faucet fitting.
IMPORTANT: Cap the sprayer
hose outlet with the included
cap. Use seal compound or
Teflon
®
tape to make a water
tight seal.
2. Remove sprayer.
3. From under sink, remove
locknut of hose guide.
Key
flow monitor
indicator ring
4. Remove hose guide and
gasket from sink hole.
5. With a utility knife, cut the
white tubing at 4 feet. Make
sure to make a clean cut at
a 90° angle.
IMPORTANT: After cutting
the tube, squeeze the tubing
back to a round shape.
6. Insert the white tubing into the
collet at the bottom of the
faucet. Make sure if tubing is
fully inserted in the collet.
7. Screw the threaded rod into
the faucet base with Phillips
screwdriver until tight.
8. Slide the flow monitor indicator
ring up to the base of the
faucet over the 48" tubing and
the threaded rod.
Make sure the key is inserted
into the key slot on the faucet
bottom.
9. Place the rubber washer on the
sink surface over the hole. Drop
the 48" tubing and faucet
assembly down into the hole
in the sink. Make sure the flow
monitor wire goes in that hole.
10. From below, install the C
shape metal retaining plate
over the threaded valve.