Terminal assignment
+, –
Supply voltage 48 V DC
(48 V)
(Input)
+, –
Supply STE 10-...
(24 V)
(Output)
bv, cv
Supply Vario bus 15 V DC
+, –
(Output)
(15 V)
Da, Db
Data cable Vario bus
CD6, 1
Triggering Door loud-
speaker
E, G
Electrically isolated input,
10–30 V DC
Evaluation via Vario bus
Terminal E = +
Terminal G = –
RS232
Interface for connecting
the STE 10-... to the
SKI 700-...
LAN
Network connection for
(ETH1/
configuration
ETH2)
ETH1: 192.168.1.250
ETH2: DHCP
Installation: Access Professional
11 Access wiring diagram
Notes on the wiring diagram:
a) A network cable must be laid
without fail from the door station to
the distributor for configuration.
b) Terminals E and G can be option-
ally used for integrating buttons or
actuators provided by the customer
for expanding the function of the
STE 10-... (e.g. additional door
release button within the building or
external movement sensor modules
for motion-controlled activation of
the control panel).
14
Terminal assignment
V1, V2
Video signal
(two-wire FBAS)
S1–S4
Power supply and
audio transmission
D1, D2
Data transmission with
digital call and Vario bus
data transmission
+, –
Supply voltage 48 V DC
(48 V)
(Input)
+, –
Supply STE 10-...
(24 V)
(Output)
bv, cv
Supply Vario bus 15 V DC
+, –
(Output)
(15 V)
Da, Db
Data cable Vario bus
E, G
Electrically isolated input,
10–30 V DC
Evaluation via Vario bus
Terminal E = +
Terminal G = –
RS232
Interface for connecting
the STE 10-... to the
SKI 700-...
LAN
Network connection for
(ETH1/
configuration
ETH2)
ETH1: 192.168.1.250
ETH2: DHCP
Commissioning and
programming
Commissioning and program-
ming of the In-Home bus / Access
Professional are described in the
relevant system manual, which is
enclosed with the line rectifier /
server.
The user interface is configured
using the configuration software on
the enclosed USB stick. For detailed
information, see the Siedle Touch
ST 10-... programming instructions.
Final task
12 Attach the mounting plate to the
façade.
Integration by the customer must
ensure permanent protection (IP 54)
against the effect of dust and mois-
ture.
Specifications
Screen diagonal: 257 mm / 10.1"
Resolution: 1280 x 800 pixels
Installation type: Horizontal or
vertical
Operating voltage: 48 V DC
Operating current: max. 500 mA
Current consumption in idle status:
350 mA
Protection system: IP 65 from the
front
Ambient temperature:
–20 °C to +55 °C
Wall cut-out (H x D): 165 x 238 mm
for horizontal integration
Care instructions
Clean your display carefully and only
with a soft, slightly moistened cloth.
Dry, aggressive cleaning agents and
abrasive detergents can damage the
surface!
Detailed care instructions are located
in the download area of
www.siedle.com.