5 - ALARM MEMORY

If an alarm has occurred the buzzer and the turn indicators will give four signals. The alarm status history is displayed the LED when
the system is disarmed, and will remain available until the system rearmed or the ignition will be switched ON.
The flashes from the LED show what caused the alarm.
1
blink
2
blinks
3
blinks
4
blinks
5
blinks
6
blinks
7
blinks
22
06DE2142E.pmd
doors, boot have
been opened
ultrasonic volumetric
sensor triggered
bonnet has been opened
attemp to start
(ignition key/hotwire)
speedometer
input/alarm
not used / Cobra Bus
activation of speed alert
sensor input / additional
sensors
22
Alarm memory - BRIDGE 4100