Usage
LEDs
Red
Default
Sounder
•
The reader sounds 4 rapid beeps when it is powered up or restarted.
•
If specified, the reader beeps once when a token is presented.
Cable Lengths
PAC door controllers only
Cable Gauge
7/0.2 0.34mm² 22AWG
16/0.2 0.5mm² 20AWG
32/0.2 1.0mm² 18AWG
Notes
•
These figures (*) are for readers powered from the controller. The cable distances
can be increased to 1650' / 500m by locally powering the readers.
•
Locally powered readers must be connected to a UL 603 power limited Class 2
supply for US, or a ULC S318 power limited Class 2 supply for Canada.
•
If you use 22AWG / 0.34mm² cables, twist the wires and double them over before
inserting them in the crimps.
•
Maximum cable distances will be less for readers which have been set to give
Wiegand output.
Specification
Reader Range
Up to 4.0" / 100mm
Green
Access permitted
Distance from Reader to Controller
AC 2100 / 2200
750' / 250m
1500' / 500m
3000' / 1000m
Power
12V–24V DC
11
English
Red / Green
Access denied
AC 202 / 512
230' / 70m *
230' / 70m *
230' / 70m *
Current
90mA