Periodic Maintenance - GYS PORTASPOT 230 Manual De Instrucciones

Ocultar thumbs Ver también para PORTASPOT 230:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
If simultaneous use of several PORTASPOT 230 on the same electrical system, it is recommended to divide the phases
in a balanced way.
Example :
PORTASPOT 230 n°1 PORTASPOT 230 n°2 PORTASPOT 230 n°3
Power supply
DESCRIPTION OF THE PORTASPOT 230
1- Clamping force screw for
the adjustment of the clamping force
to the electrodes.
2- Handle position right / left.
3- Mobile welding arm.
4- Fixed welding arm.
5- Power cable.
6- Information Plate.
7- Welding trigger switch.
8- Handle for sheets' tightening.

PERIODIC MAINTENANCE

To ensure that the machine performance is optimal, it is required to perform regular maintenance. Once a week if the
machine is used daily, or once a month if the machine is used occasionally.
- Remove the arm, caps holders, and caps
- Brush scotch brite on the aluminium bores on clamp and arms' nuts and lubricate with Gel 452
- Brush the caps holders, then grease with Gel 452
- Reassemble and replace caps
SETTINGS
1- Welding time:
This function allows you to adjust the welding time around the AUTO value set by the machine.
2- Sheet thickness:
This function allows you to select the thickness of the sheet: 0.6 mm + 0.6 mm to 2 mm + 2 mm.
3- Welding mode:
This selection improves the welding capacity on hard steels or on metal sheets with a special protective
film. The pulse period is automatic and requires no adjustment.
14
PORTASPOT 230
L1-N
L2-N
: Multi pulse welding current.
: Welding current with one impulse
L3-N
8
3
4
PORTASPOT 230 n°4
L1-N
1
7
5
2
EN
...etc
...etc
6

Publicidad

Tabla de contenido
loading

Tabla de contenido