□ THE PUSH LEVER AND TRIGGER MUST MOVE
SMOOTHLY WITH PULLING BACK THE NAIL
FEEDER.
Push Lever
(2) Adjust the air pressure to 70 psi (4.9 bar 5 kgf/cm
Connect the air hose.
Do not load any nails in the Nailer.
□ THE NAILER MUST NOT LEAK AIR.
Hold the Nailer downward and pull the trigger with
pulling back the nail feeder.
□ THE NAILER MUST NOT DRIVE.
Pull Trigger
(3) With fi nger off the trigger, depress the push lever
against the workpiece.
□ THE NAILER MUST NOT DRIVE.
Do not connect
air hose
Nail Feeder
Nail Feeder
Do not pull Trigger
Depress Push Lever
(4) Without touching the trigger, fi rst depress the push
lever against the workpiece.
Pull the trigger with pulling back the nail feeder.
□ THE NAILER MUST DRIVE.
).
2
(5) With the Nailer off the workpiece, pull the trigger.
Depress the push lever against the workpiece.
□ THE NAILER MUST NOT DRIVE.
(6) If no abnormal operation is observed, you may load
nails in the Nailer.
Drive nails into the workpiece that is the same type to
be used in the actual application.
□ THE NAILER MUST DRIVE PROPERLY.
ADJUSTING AIR PRESSURE
Adjust the air pressure at recommended operating
pressure 80 – 120 psi (5.4 – 8.3 bar 5.5 – 8.5 kgf/cm
according to the length of nails and the hardness of
workpiece.
The correct air pressure is the lowest pressure which will
do the job. Using the Nailer at a higher than required air
pressure unnecessarily over stresses the Nailer.
English
WARNING
● Do not exceed
120 psi (8.3 bar
8.5 kgf/cm
).
2
)
2
13