• CONFIGURATION
The Door Controller settings are set via the Programming Button and displayed
by the signalling LEDs.
LED signals and programming functions:
OPERATION:
LED 1 flashing - degraded mode (no polling - OFF-Line)
LED 2 flashing - RS485 polling (only if configured on the Network Controller)
LED 3 flashing - LAN polling (only if configured on the Network Controller)
LED 4 fixed - saving settings in EEPROM
LED 5 fixed - writing card archive
LED 6 steady - historical list to be transmitted (OFF-Line events)
PROGRAMMING:
To access the programming function:
1. Press the button briefly in order to access the programming function.
2. It automatically positions itself on function 1: LED 1 steady.
3. Press the button
4. Pressing it longer accesses the selected function.
(when all the LEDs flash quickly it means that you have pressed it for a suffi-
ciently long time).
Available functions:
Functions
1
view and modify a logical address (from
2
view and modify the RS485 baud-rate
3
4
5
6
(settings, archives and connection parameters LAN and RS485)
Door Controller
n
times to go to the required function.
Description
1 to 32)
(from 1 to 5)
enabling / disabling DHCP
clear settings and archives
Restore to Factory Default
not used
24
Default
32
57600
532226 - Rev. D