Function 1 - View and modify logical addresses:
enable the function by pressing the Programming Button.
Turn on the "LED 1" - press and hold the button until all the LEDs flash, release it.
The six LEDs display the set ID number in binary mode.
Each time the Button is pressed it advances by one unit.
8
1
2
ID1
ID2
ID3
ID4
ID5
ID6
ID7
ID8
ID9
ID10
ID11
ID12
ID13
ID14
ID15
ID16
To confirm the value displayed, keep the Programming Button pressed until all
6 LEDs flash quickly to indicate that the value has been confirmed.
Door Controller
The default address is 32 (led 6 lit)
LED
3
4
5
6
Translation of the original instructions
1
ID17
ID18
ID19
ID20
ID21
ID22
ID23
ID24
ID25
ID26
ID27
ID28
ID29
ID30
ID31
ID32
25
LED
2
3
4
5
532226 - Rev.D