Imer Group SPIN 30 Manual De Uso, Mantenimiento Y Repuestos página 18

Mezclador continuo
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

- Caution! The first time the water pump is connected
to the tank it must be primed by filling the intake line
manually. The same operation must be repeated each
time the circuit is drained, or after a prolonged period of
disuse.
10.3 Connection to a storage silo
If the mixer is to be connected to a storage silo, an optional
transfer system must be used, such as the model IMER TWISTER
or similar, which, connected between the silo and machine,
transfers all material automatically.
To connect the transfer system to the mixer, the optional filter
cover must be installed
(Code no. IMER 1107502):
- Remove the bag splitter grid or hopper grid.
- Install the cover and tighten the tie-rods of the connections.
11. START-UP(see fig.7)
- During work start and stop the mixer exclusively by
means of the ON/OFF switch.
3-PHASE VERSION
Turn the switch/inverter (ref.5) in one of the two directions, turn
the thermal magnetic switch (ref.1) to ON(1), the machine is
ready for operation. At this point, it is important that the direction
of rotation
of the auger (ref.6,fig.1), is in the direction indicated by the
arrow (ref.4); if not, turn off the mixer by setting the thermal
magnetic switch to OFF(2).
Reposition the switch/inverter. Restart with the thermal magnetic
switch set to ON(1). The direction of rotation should now be
correct to start work. As soon as the correct direction of rotation
of the auger is ensured, leave the switch/inverter in position until
the machine is to be moved. Then use exclusively the thermal
magnetic switch (ON/OFF) for operation.
PHASE 1:
-Set the ON/OFF switch to ON(1).
-Setting the quantity of water required for mixing by means of
the micrometric valve (ref.9,fig.1).
Adjust the flow meter (ref.10,fig.1):
to bring the water level to approx. 600 l/h.
-Set the ON/OFF switch to OFF(1).
PHASE 2:
- Load the pre-mixed dry material Take the bags of material and
place them securely on the bag splitter grid
(ref.12,fig.1), lift the two end corners of the bag to completely
empty the contents into the hopper (fig.6).
FIG.6
-At this point position a suitable container below the material
outlet and start up the mixer by means of the ON/OFF switch.
The machine should now be in operation
IMER INTERNATIONAL S.p.A.
SPIN 30
To obtain the required material consistency:
Optimise the quantity of the water delivered by means of the
micrometric valve, while the mixer is in operation.
Make small adjustments of approx. 1/2 turn, every 15 seconds.
The machine is fitted with protection against power failure: if
this occurs, press the start pushbutton to resume operation.
To stop the machine in the event of an emergency, press the
red emergency button (ref. 3); all moving parts are shut down
Then turn the main switch to 0 and disconnect the electric
power plug.
THERMAL CUT-OUT PROTECTION:
by thermal magnetic cut-outs, the activation of which is
indicated by total shutdown of the machine. In this case,
authorised personnel should wait for the motors to cool
and restart the unit by means of the ON/OFF switch.
inside the electrical panel. Before opening, ensure that
the power plug is detached from the electrical panel. In
the event of a fault, only qualified personnel must access
the machine for repairs.
12. OPERATION
the grid must be removed only after disconnecting the
plug from the electrical panel, reconnecting only after
fitting the filter cover.
starting work.
12.1 Pauses during work
Interruptions exceeding 30min should be avoided.
Prolonged shutdown can cause clogging in the mixing chamber.
If no material exits the discharge outlet, this must be cleaned.
Stop the machine, proceed as described in para. 13, refit and
restart the unit.
rotates in the opposite direction to normal operation, the
machine must be shut down immediately to prevent entry of
water in the hopper. This would cause damage to the material
in the hopper, which to ensure correct use must remain
completely dry.
18
- The electric motors are protected against overload
- The water pump is also protected by means of fuses
- The hopper safety grid must always be fitted.
- If using the mixer connected to a transfer system,
- Wear envisaged personal protection devices before
- When the mixing chamber is clogged or the machine