PROBLEMS
Machine does not start
Electric current
- No current delivered to connector of site panel (fuses?)
- No power delivered to machine
(defective connector connection? loose cable?)
- Main ON/OFF (thermal cutout) switch not turned on
- Main switch/inverter (3-PHASE version only) set to position 0
- Mixing chamber open
(thermal magnetic switch does not engage)
- Emergency pushbutton pressed (release)
Thermal cutout trips on
Material in hopper
start-up
- Material has hardened in the hopper
- The type of material requires more water for mixing
Material consistency not
Water supply insufficient
constant; too hard or too
- Water hose bent
fluid
- Pump inlet water filter clogged
- Pressure reducer water filter clogged
- Pressure reducer faulty
The water continues to exit
Solenoid valve faulty
from the mixing chamber
when machine is
stationary
Material does not exit the
Mixing chamber clogged
offload port
- The container used for offload is too high and does not enable
the material to flow out
- The offload port is clogged
Mix not optimal
The type of material used is not suitable
- Not all products on the market can be mixed with this type of high
speed mixing system
- Mixing shaft worn
INDICATOR LIGHT
GREEN (ref. 1g, FIG.10)
IMER INTERNATIONAL S.p.A.
CAUSES
ON
Electric power supply correct, phase sequence correct
SPIN 30
- Check points listed alongside
- Completely empty the hopper and restart with new material
- Increase the quantity of water delivered
- Check points listed alongside
- Contact an authorised IMER service centre
- Check points listed alongside
- Consult the material manufacturers to check compatibility
- Replace shaft
- Electric power failure
- Phase failure
- Incorrect phase sequence
- Main switch set to 0
21
CORRECTIVE ACTION
OFF