Structure of instrument
The FUTURO SURFACE COMPACT VHF is supplied with an adapter, connected 
directly with the instrument, and an extension cable for measuring directly 
with the handier traverse unit. This enables free measurements, to reach 
badly accessible measuring spots, and to effect measurements by means of 
a measuring support as well   -   unavoid-able for measuring with skidless 
tracers.
Setting of language
1.  Press any key – the instrument will be ready for operation within a 
few seconds
2.  Press button ‚M' in the display appears the menu
3.  Press the button ‚R' twice to configuration
4.  Press the button ‚M' once
5.  Press the button ‚R' four times  to system
6.  Press the button ‚M' once
7.  Press the button ‚R' once
8.  Press the button ‚M' several times, the further languages will appear 
one after the other
9.  After having reached the requested language, press the button ‚Lt' once
10  Press the button     , till you are again in the measure mode
Calibration
1.  Press any button, after some seconds, the instrument is ready for 
operation
2.  Press button ‚M' in the display appears the menu
3.   Press the button ‚R' four times  to Calibration
4.  Press the button ‚M' once
5.  Press the button ‚R' once  to Reference
For the calibration, the cutoff 0.8 mm is set automatically!
6.  Press the button ‚Lt' or ‚R', if you do not calibrate with the original 
metal calibration piece
7.  Press the button ‚M' once
8.  Press the button ‚R' once  to cal Ra/Lt
9.  Press the button ‚M' once and confirm again with ‚M'
10. The calibration procedure (4 measurements) lasts one minute 
approximately
11. Press the button      , till you are again in the measure mode
Connections
Under the cover there are connections for: Main adapter, USB
Brütsch / Rüegger Werkzeuge AG • Heinrich Stutz-Strasse 20 • Postfach • 8902 Urdorf • Tel. +41 44 736 63 63 • Fax +41 44 736 63 00 • www.brw.ch • sales@brw.ch
When using as one-hand ope-rated instrument, 
the traverse unit (picture below) with inserted 
roughness tracer is connected directly with the in-
strument housing. It is suitable to effect roughness 
measurements on even or round sur-faces.
One-hand ope-
rated instrument 
with tracer
The traverse unit and the adapter, held by two fixing balls in the instru-
ment, must by no means be inserted obliquely, as this could cause damage
of the plug-contacts.
Tracer
Remove the supporting shoe by using the enclosed hexagon key or by means 
of the knurled nut (type VHF). 
The tracer is now inserted into the traverse unit that the point in the middle 
is facing the prism. 
Warning: By no means is the tracer to be inserted forcefully; it must be held
with the utmost care at its largest diameter! If manual measurements are to
be effected, remount the supporting shoe to the traverse unit once again.
The position of the supporting shoe is correctly reached when the work piece 
is supported on its whole length by the traversing unit with supporting shoe. 
If the measuring area is too small, the bottom surfaces of traversing unit and 
supporting shoe must be on the same level.
Keyboard
Key
Measuring mode
Start measuring
Menu for  configuration of 
instrument
Selection of traversing length
Recall of the measuring values  
Measuring
The area to be measured on the work piece must be properly cleaned in 
order to avoid that the tracer getting dirty. If the roughness is measured 
manually, the tracer is laid onto the work piece and held steadily. The green 
indicator LED on the instrument must be on, confirming that the tracer and 
the instrument are in condition ready to measure. After pressing the start key, 
the measuring procedure is effected automatically. Shortly after, the measu-
ring values can be read on the LCD-display and printed out.
Pressing any key can interrupt a current measuring operation and bring the 
tracer to a halt. The measuring operation must be started again, to bring
the tracer to its starting position again.
Menu function
Confirmation
Menu switch on/ off / Escape
Selection of menu – previous 
menu point
Selection of menu  -  next menu 