Instructions for installation and use
● Observe the minimum and maximum supply water pressure speci-
fied in the technical data (see 11. Technical data on page 12).
● A drain must be located at the bottom of the sauna room in case
the water line is damaged or begins to leak.
● For the connection, only use the hose set included or one obtained
from customer service. Under no circumstances should you use
existing or previously used hose sets.
● For your own safety, consult your supplier in the event of prob-
lems that are not explained in sufficient detail in the installation
instructions.
3. Product description
3.1. Scope of delivery
● Auto-refill unit with water connection pipes
● Mounting screws
● Sealing ring
● Instructions for installation and use
3.2. Product functions
The auto-refill set works based on the principle of filling level meas-
urement. If the level of the water in the evaporator tank drops, the
float loses buoyancy and therefore opens the water valve on the
auto-refill unit. This valve ensures that fresh water flows into the
evaporator tank until the float rises and makes the water valve
close again.
p. 5/12
EN