TEST CONNECTIONS
All connections and joints must be thoroughly tested for leaks in accordance with local
codes and all listed procedures in the latest edition of the National Fuel Gas Code ANSI
Z223.1/NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1, or Propane
Storage and Handling Code, B149.2, or the Standard for Recreational Vehicles, ANSI A
119.2/NFPA 1192, and CSA Z240 RV Series, Recreational Vehicle Code, as applicable.
Do not use an open fl ame to check for gas leaks. Be sure
there are no sparks or open fl ames in the area while you
check for gas leaks. This will result in a fi re or explosion
which can cause serious bodily injury or death, and damage
to property.

CONNECT GAS SUPPLY

1)
Uncap the fl are fi tting from the optional side burner connection located at
regulator.
Note: You must connect your side burner to a Weber
#62434) located at main gas supply. If you do not use a Weber
Warranty on the Summit
®
Built-In Side Burner will be voided. If you have any questions,
contact Customer Service at 1-800-446-1071.
2)
Connect the corrugated gas line to the side burner Connection.
SIDE BURNER NG SUPPLY CONNECTIONS
1
Cap (Optional Side Burner)
2
Hard Piped Gas Supply
3
4
a
Top View
WWW.WEBER.COM
®
GAS INSTRUCTIONS
DANGER
®
approved regulator (part number
®
approved regulator the
Regulator
To SIde Burner
TEST CONNECTIONS
All connections and joints must be thoroughly tested for leaks in accordance with local
codes and all listed procedures in the latest edition of AS5601/AG601.
Do not use an open fl ame to check for gas leaks. Be sure
there are no sparks or open fl ames in the area while you
check for gas leaks. This will result in a fi re or explosion
which can cause serious bodily injury or death, and damage
to property.
WARNING: You should check for gas leaks every time you discon-
nect and reconnect a gas fi tting.
Note - All factory-made connections have been thoroughly checked for gas leaks. As
a safety precaution however, you should recheck all fi ttings for leaks before using your
Summit ® Built-In side burner. Shipping and handling may loosen or damage a gas
fi tting.
You will need: a soap and water solution, and a rag or brush to apply it.
Turn on gas supply.
Check for leaks by wetting the connections with the soap and water solution and watch-
ing for bubbles. If bubbles form or if a bubble grows, there is a leak.
Note - Since some leak test solutions, including soap and water, may be slightly cor-
rosive, all connections should be rinsed with water after checking for leaks.
WARNING: Do not ignite burners when leak checking.