Notes
These￿figures￿(*)￿are￿for￿readers￿powered￿from￿the￿controller.￿The￿cable
distances￿can￿be￿increased￿to￿1650ft￿/￿500m￿by￿locally￿powering￿the￿readers.
Locally￿powered￿readers￿must￿be￿connected￿to￿a￿UL￿603￿power￿limited￿Class￿2
supply￿for￿US,￿or￿a￿ULC￿S318￿power￿limited￿Class￿2￿supply￿for￿Canada.
If￿you￿use￿22AWG /￿0.34mm²￿cables,￿twist￿the￿wires￿and￿double￿them￿over
before￿inserting￿them￿in￿the￿crimps.
Maximum￿cable￿distances￿will￿be￿less￿for￿readers￿which￿have￿been￿set￿to￿give
Wiegand￿output.
Specification
Card
<￿2.0in￿/￿50mm
Temperature
Operating
-40°C￿—￿+66°C￿/￿-40°F￿—￿+151°F
Humidity
Operating￿for￿24￿hours
10-85%￿RH￿@￿30±2°C￿/￿85±4°F
Ingress￿Protection
IP65￿after￿installation.￿Installer￿must￿adequately￿seal￿any￿connections￿made.
Token
<￿1.1in￿/￿30mm
Power
12V￿—￿+24V
Storage
-40°C￿—￿+66°C￿/￿-40°F￿—￿+151°F
Tested￿at￿93%￿for￿ULC￿S319.
9
English
Current
<￿100mA