1.0 GENERAL
The DV-12 is a time controlled relay box with
which a maximum of 2 x 600 watt fittings or
2 x 400 watt fittings can be switched.
1.1 TECHNICAL DATA
Dimensions
Required voltage
Max. Output
Isolation level
1.2 REQUIRED (ACTIVE) VOLTAGE DV-12
To connect the DV-12 you will preferably need a
'clean' group of at least 6 Amp. A 'clean' group
means that this group will only be used by the by
the DV-12. If you do not have a(n) (extra) 'clean'
group we advise you to have the DV-12 installed
by a certified installer.
The DV-12 has a 6 Amp thermal fuse.
This fuse turns off the DV-12 automatically in
case of an overload and / or a short circuit..
1.3 THE INSTALLATION OF THE DV-12
At the back of the DV-12 there are 2 mounting
brackets. This allows you to mount the DV-12
onto a (flat) surface.
CAUTION!
The analogue timer is a sensitive part of the
DV-12, and is not resistant to hard shocks.
• Place the DV-12 close to your 'clean' group.
• At the bottom of the DV-12 you will find a
grounded (230V) connection cord
DV-12 Binnenwerk PMS.indd 5
Manual DV‑12
• Install, if needed, a grounded outlet onto your
• Plug the cord into the outlet of your 'clean'
• Your DV-12 is now connected to the mains
: 110 x 210 x 70mm.
1.4 CONNECTING EQUIPMENT TO THE DV-12
: 230 Vac / 50Hz.
You can connect 2 x 600 watt or 2 x 400 watt
: 6 Amperes.
fittings to your DV-12.
: IP-44
In steps 1.2 and 1.3 you have;
• Connected your DV-12 to a 'clean' group,
• Mounted it onto a flat surface,
• Connected it to the mains voltage.
Now the electrical ballasts (fittings) will have to
be connected to the DV-12.
Please read the installation manual carefully
before you connect the electrical ballasts, in
order to connect them properly.
If the electrical ballasts have been properly
connected there will be a 230V cord on each
of the electrical ballasts. Plug both cords of
the electrical ballasts into the power outlets
(sockets) on the side of the DV-12. You now have
connected 2 electrical ballasts to the DV-12.
1.5 ADJUSTING THE DV-12 FOR USE
The DV-12 is now ready for use; we only have to
adjust the time.
• Remove the plastic cap of the time switch.
• On the right side of the clock you will find a
'clean' group.
group.
voltage.
3-position switch.
7
30-10-2012 14:08:21