Designation of use:
Maximum static pressure:
Minimum working pressure:
Maximum working pressure
Recommended working pressure (hot &
cold):
Max hot water temperature:
Recommended hot water temperature:
Recommended cold water temperature:
Flow rate (bath):
Recommended maximum set mixed water temperatures
Application
Bath:
Shower:
Bath/Shower:
1. Valves operating outside these conditions of use cannot be guaranteed to operate as
intended.
2. The thermostatic mixer is pre-set to a safety stop temperature of 38 °C. Since operating
conditions in each supply system varies, it might be necessary to calibrate the mixer
according to the service and installation instructions.
3. You can override the safety stop temperature by pressing the override button.
4. Hot and cold supply pressure should be balanced.
5. The thermostatic mixer is for use with shower heads with a flow rate of 7 l/min (1.8 gpm)
or higher.
6. To avoid burn injuries, the maximum temperature of the outlet water must be no higher
than 49 °C (120 °F) – In Massachusetts, no higher than 44.5 °C (112 °F).

OPERATING CONDITIONS

HP (high pressure supply system)
10 bar (145 PSI)
0.5 bar (7.25 PSI)
10 bar (145 PSI)
1 – 5 bar (14.5 - 72.5 PSI)
80 ˚C / 176 ˚F
60 - 65 ˚C / 140 - 149 ˚F
10 - 15 ˚C/ 50 - 59 ˚F
20 l/min (5 gpm) @ 3 bar (43.5 PSI)
Maximum outlet temperature
46 °C / 115 ˚F
43 °C / 109.5 ˚F
43 °C / 109.5 ˚F
4