TAB: 7548
Before answering the LED associated to the
it was flashing previously to indicate missed calls.
Answering the current call from the switchboard also causes the flashing
to stop once the indoor station returns to stand-by (only on the indoor
station the call was answered from). The same result can be obtained
by also reactivating the ringtone, by making an intercom call, or by an-
swering a call.
N.B.: the missed call signal remains also in the case of a power outage.
Lock command
In standby mode (handset hung up) or during a conversation, pressing
the
button sends the unlocking command (by default the last call-
ing entrance panel).
Self-start with dedicated button (button
To self-start to the master panel, briefly press the
the communication, lift the handset. Replace the handset to end the
conversation.
Calling the concierge switchboard
To make a call to the concierge switchboard (if installed in the system),
raise the handset and send the call by pressing the
Alert
Internal Unit 7548, together with porter switchboard Art. 40510, creates
a system that can send an alert to the switchboard operator even when
the Due Fili bus is busy. In contrast to other internal units, it is possible
to use only the pair of terminals FP-M as an input, not the buttons. In this
case the local landing call function is lost. The FP-M operating mode is
selected using SaveProg.
1. Activate input FP-M. See below for the description of the two activa-
tion possibilities.
2. The internal unit waits to receive the alert from the switchboard. In
the meantime, the chosen signalling is sent to the user according to
the table below. On receipt of the message, the switchboard emits a
double beep and displays a red envelope icon to alert the operator.
3. If it does not receive a replay, the internal unit resends the message
every 10 s. After 5 attempts with no reply the internal unit stops send-
ing the messages.
4. When an internal unit receives confirmation of the receipt of the mes-
sage by the switchboard, the chosen signalling is sent to the user
according to the table below. Normally the time between the sending
of the request and confirmation of reception is less than a second.
5. Until the switchboard calls the internal unit to service the request, the
internal unit resends the message every 120 s. At each message,
the switchboard emits two meets and increases count of messages
received. The counter can be viewed by opening the list of alerts in
the switchboard. The sending of messages never terminates. It con-
tinues until the end of the service described in the next point, unless
the switchboard is powered off or removed from the system, in which
case the internal unit, after 5 unsuccessful attempts starting from the
first timeout of 120 s, will return to standby mode and the LED on the
LOCK key will stop flashing.
6. If the switchboard operator calls the internal unit from the list of warn-
ings, and only from this, a message is sent to the internal unit via the
Due Fili bus to end the Alert procedure so the relative signal is no
longer sent to the user.
Note: if the internal unit is switched off, when it is switched back on again
the function starts again from the beginning.
Alert Configuration
Use SaveProg to select some of the characteristics of the Alert function:
1. Enabling
a. Disabled (default)
b. Enabled
button stops flashing, if
2. Polarity state active
a. Contact normally open (default)
b. Contact normally closed
3. Activation delay
a. 0.1 s (default)
b. 0.5 s
c. 1 s
d. 2 s
4. Signalling mode
a. None
b. LED associated to the Stair Light button (default)
c. Sound
According to the selected signalling type, apart from the first, the timer
is as follows:
The internal unit waits to
)
receive the alert from the
switchboard
button. To stop
The internal unit has re-
ceived confirmation of the
receipt of the message from
the switchboard
button.
Configuring with SAVEPROG Software
SaveProg is PC software designed for advanced configuration of Due
Fili Plus Systems.
Updating
The device is updated via USB connection.
Follow the WinBoot operating instructions.
To update the device:
1. disconnect it from the Due Fili bus
2. connect it to the PC via USB
3. start the WinBoot update within 30 seconds.
EN
STATE
LED timer
Flashing with a
cycle of 0.5 s on /
0.5 s off
Flashing with a
cycle of 0.1 s on /
0.1 s off
Sound timer
A 2 KHz tone for
0.2 s
A 1 KHz tone for
0.1 s
21