DirectHome MEDICAL SleepWeaver Anew Manual Del Usuario

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Technical Specifications (cont.)
4. Anti-Asphyxia Valve (AAV) operation:
Open to atmosphere @ 1.6 cm H
Close to atmosphere @ 2.1 cm H
5. Fixed leak rate (flow may vary due to manufacturing variation):
Pressure (cm H
0)
4
5
2
Flow (LPM)
16
18
6. Environmental storage and operating conditions are not expected to effect the
function of this device.
Cautions & Warnings
Does not contain natural rubber latex. If you have any reaction to any part of this mask or
headgear discontinue use immediately.
In the USA, federal law restricts this device to sale by, or on the order of, a physician.
This system should be used only with the PAP system recommended by your physician or
respiratory therapist.
This mask should not be used unless the PAP machine is turned on and operating properly.
The vent holes should never be blocked.
Please refrain from smoking while using this product.
The SleepWeaver Anew should not be cleaned with unapproved cleaning and
disinfecting methods.
The mask should be cleaned daily to prevent dirt and oil contamination from the skin
building up on the mask.
The patient should clean their face prior to wearing the mask.
Ensure the mask is put on correctly. The oral portion of the mask contains the
90
Elbow AAV.
o
The patient should not alter the design of the mask.
Do not place the mask in a clothes dryer.
Do not block or disable the AAV on the SleepWeaver Anew.
The SleepWeaver Anew is not intended to be used on patients that are uncooperative,
obtunded, unresponsive, or unable to remove the mask without clinical supervision.
If the SleepWeaver Anew is being used with supplemental oxygen, the oxygen flow must
be turned off if the machine is not operating because accumulated oxygen is a fire hazard.
If the SleepWeaver Anew is being used with supplemental oxygen, the patient should
refrain from smoking.
To minimize the risk of vomiting during sleep, the patient should avoid eating or drinking
for three hours before using the mask.
The SleepWeaver Anew is for single patient re-use only and is not approved for clinical
cleaning and disinfecting methods.
• At low pressures the flow through the ventilation holes may be inadequate to clear all
exhaled gas from the tubing. Some rebreathing may occur.
Contraindications
The SleepWeaver Anew should not be used in conjunction with a volume ventilator that
requires a non-vented mask.
The SleepWeaver Anew is not intended to be used by those patients that are taking
prescription drugs that may cause vomiting.
The SleepWeaver Anew may not be suitable for persons with the following conditions:
impaired cardiac sphincter, excessive reflux, impaired cough reflex, or hiatal hernia.
Limited Warranty
www.circadiance.com/help
101083 REV 3
EMERGO EUROPE
Molenstraat 15
2513 BH, The Hague
The Netherlands
Tel: +31 (0)70 345 8570
0459
O
2
O
2
10
15
20
25
30
41
50
58
English
1060 Corporate Lane
Export, PA 15632 USA
Phone: 888-825-9640 or +1-724-858-2837
cservice@circadiance.com
www.Circadiance.com
30
67
Intended Use
The SleepWeaver Anew Soft Cloth Full Face PAP Mask is intended to provide an
interface for Positive Airway Pressure (PAP) therapy. This mask is intended for
single-patient reuse in the home and in the hospital/institutional environment.
This mask is to be used on patients greater than 66 lbs (30 kg).
Mask Orientation
1. Remove your SleepWeaver Anew from the package.
2. Understand the proper orientation of the mask:
a. Oral interface covers your mouth
1. Contains 90
2. Contains exhalation holes
3. Contains mask size (Small, Regular, Large)
b. Nasal interface covers your nose
a. / 1.
a. / 2.
a. / 3.
Elbow Anti-Asphyxia Valve (AAV)
o
b.

Publicidad

Tabla de contenido
loading

Resumen de contenidos para DirectHome MEDICAL SleepWeaver Anew

  • Página 1 2. Understand the proper orientation of the mask: for three hours before using the mask. • The SleepWeaver Anew is for single patient re-use only and is not approved for clinical a. Oral interface covers your mouth cleaning and disinfecting methods.
  • Página 2: Technical Specifications

    Cleaning the Mask 1. Your SleepWeaver Anew should be cleaned by hand washing with a mild nonabrasive soap in warm water every other day. Never use hot water. Repeat washing until visibly clean. Hand wash the headgear weekly.
  • Página 3: Precauciones Y Advertencias

    1. Contiene el Codo de 90 con Válvula Antiasfixia (AAV, por sus siglas en • La mascarilla SleepWeaver Anew está diseñada para que un solo paciente la reutilice y inglés) no está aprobada para métodos de limpieza y desinfección clínicos.
  • Página 4: Especificaciones Técnicas

    Cómo Limpiar la Mascarilla 1. La SleepWeaver Anew debe limpiarse luego de cada uso, lavándola a mano con jabón suave no abrasivo y agua tibia. Nunca utilice agua caliente. Repita el lavado hasta que esté visiblemente limpia. Lave el arnés a mano semanalmente.
  • Página 5: Précautions Et Mises En Garde

    à domicile ou en environnement hospitalier/insti- • Ne bloquez pas et ne désactivez pas la valve anti-asphyxie sur le masque SleepWeaver Anew. • Le masque SleepWeaver Anew n’est pas destiné à être utilisé sur des patients peu coopéra- tutionnel.
  • Página 6: Spécifications Techniques

    à ouverture rapide. Nettoyer le masque 1. Votre SleepWeaver Anew doit être nettoyé à la main avec un savon doux non abrasif et de l'eau tiède un jour sur deux. N’utilisez jamais d'eau chaude. Renou- velez le lavage jusqu'à ce que le masque soit visiblement propre. Lavez le harnais chaque semaine.

Tabla de contenido