Three-Wire Power Cord
• A 3-wire connection is NOT permitted
on new construction after January 1,
1996.
• A UL-listed strain relief is required.
• Use a 30-amp, 240-volt, 3-wire, UL-listed power
cord with #10 AWG-minimum copper conductor and
closed loop or forked terminals with upturned ends.
1
Remove the terminal block access cover on the
upper back of the dryer.
2
Install a UL-listed strain relief into the power cord
through-hole.
3
Thread a 30-amp, 240-volt, 3-wire, UL-listed
power cord with #10 AWG-minimum copper
conductor through the strain relief.
UL-Listed 3-Wire Power Cord
4
Attach the two hot leads (black and red) of the
power cord to the outer terminal block screws.
5
Attach the neutral (white) wire to the center
terminal block screw.
NOTE
The dryer is supplied with the neutral conductor
grounded. If a 3-wire cord is to be used and is
allowed, make sure the white neutral grounding
wire is connected to the green ground screw.
6
Connect the external ground (if required by local
codes) to the green ground screw.
7
Tighten all screws securely.
MFL70442605_en_190215.indd 29
8
Terminal Block
UL-Listed
Strain Relief
INSTALLATION
Reinstall the terminal block access cover.
Hot
Neutral
(Black)
(White)
Ground
Screw
White Wire
from Dryer
harness
External Ground
Wire (If required
by local codes)
29
Hot
(Red)
2019-02-15 오후 2:38:22