ERROR MODE

meaning of Error Codes that lED displays during occurrence or problem.
Dryer error code
PROBlEm
It is displayed when thermistor is open or short. Thermistor should be replaced
It is displayed when thermistor temperature
have increased about 17 degrees for
10 seconds
It is displayed when blower fan motor is re-
strained.
It is displayed when thermistor temperature
have increased about 35 degrees from 5 to 10
minutes after starting.
It is displayed when airflow switch is open more
than 30 seconds When motor RPM is more than
600, It is displayed when airflow switch is open
more than 20 seconds.
It is displayed when airflow switch is open for 3
seconds after starting.

POWER FAIl RECOVERY

In case of power failure the machine stops running but the time display remains on, showing the time just before
power failure.
Press the Start button after the power is restored, then the machine will restart.

DEFAUlT DRYER SETTINgS

Default Settings
Cycle Time (Minutes)
Cool Down Time Cycle
High Temperature
Medium Temperature
Low Temperature
Top Off Time (Minutes per coin)
Coin #1 Value
Coin #2 Value
Minutes/Minutes and seconds
Temperature Unit
Error Mode
All manuals and user guides at all-guides.com
POSSIBlE CAUSE
SOlUTION
Thermistor should be replaced
Fan motor should be checked
Check the gas supply condition
Press reset switch during operating once and
then, check ignition operating
Check lint filter, exhaust duct, blower fan, and
front duct
Check air flow switch and drum motor
Default
5 Minutes
2 Minutes
143.6° F (62° C)
131° F (55° C)
116.6° F (47° C)
5 Minutes
25 ¢
25 ¢
Minutes
Celsius
On