28
UK
WARNINGS FOR THE USER
In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical Service.
Periodically check functioning of the safety devices. Any repairs must be carried out by specialised personnel
using original and certified materials.
The appliance is not to be used by children or people with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or instruction
WARNING: IMPORTANT SAFETY INSTRUCTIONS
It is very important to follow the present instructions for your own safety.
Please keep this manual.
ELECTRICAL CONNECTIONS: FASTONS
1
CF1 CF2
COLLEGAMENTI ELETTRICI: MORSETTIERE
Terminal
Position
1
2
3
4
5
JP1
6
7
8
9
10
11
12
13
JP4
14
15
16
17
18
JP3
19
Secondary connection of 24Vac transformer
Description
Signal
AC
Battery charger equipment connection
AC
Battery charger equipment connection
+SK
Battery charger equipment connection
-SK
Battery charger equipment connection
M1
Motor 1
M1
Motor 1
M2
Motor 2
M2
Motor 2
LAMP
Flashing light output 24V 10W max.
LAMP
Flashing light output 24V 10W max.
COM
Electric lock negative (common)
EL1
Electric lock 1 +24 Vdc positive - motor 1
EL2
Electric lock 2 +24 Vdc positive - motor 2
COM
External accessory power supply negative (common)
SPIA
Warning light output 24Vcc 3W MAX
+ ACC
+24Vcc external accessory power supply (photocells, radio, etc.)
+ SAF
+24Vcc external safety device power supply.
START
START input (N.O.)
PEDESTRIAN input (N.O.)
After an emergency intervention (SAFETY or AMPEROMETRIC) with motion inversion
PED
of the second leaf, the pedestrian command will activate both leafs to prevent them
from overlapping.
Working:
Fast flashing in opening, off during pause,
fast flashing in closing
BA24