Descargar Imprimir esta página

Bticino MyHome 4073 Manual Del Usuario página 3

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
OUTDOOR SIREN WITH FLASH
Acoustic and optical outdoor warning designed to
contain the self-supply battery.
Acoustic
signaller
Optical
signaller
OUTDOOR SIREN INSTALLATION
1
5
3
7
4
6
5
10
Cable
Cut-outs for
passage
installation
with pipes on
surface
1
1
2
1
8
Wall
11
Battery
housing
Siren flash LED
1
1
1
1
Features
The MAX at the input terminals:
- normal operation
- alarm
- battery charging with E47ADCN
Input/output and power supply
Housing for 12V battery
Alarm autonomy
Alarm sound intensity
Frequency
Flashing
Flashes per minute
Weight (without battery)
IP degree of protection
Room operating temperature
Self-protected against removal and
opening
Protection index against mechanical
impact IK
• Unscrew the 4 screws (1) and remove the external cover (2).
• Using the drilling template (3), position the hole (4) by the wires out pipe,
and mark the 4 holes for the fastening screws (5), the hole for the tamper
screw (6) and the hole for the anti-tamper fastening (7) (Patent Pending).
NOTE: drill the holes using a Ø 6 mm drill bit.
• Insert the plastic plugs into the holes.
• Break the hole cut-out (11) to insert the screw of the anti-tamper system.
• Partially screw the two top screws and attach there the siren (8).
• Screw the two bottom screws (9). Tighten all four fastening screws and the
9
screw of the anti-tamper system.
• Screw the tamper screw (10); if the device is being installed on an uneven
surface avoid excessive tightening.
• Insert the battery in its housing without connecting the Faston clamps. For
the type of battery see the following table:
Power supply
Main battery
E49
7 Ah
E46ADCN
7 Ah
E47ADCN
2 Ah
(*) If the second siren is installed in order to have an additional signalling and it
is not necessary to extend the system autonomy in back-up mode (no network
supply), it is possible to install a 2Ah battery.
• Connect the supply cable pair (BUS) to the appropriate clamps of the
internal card (see following page).
• Connect the battery connectors only with powered BUS.
• Fit the cover and screw the four fastening screws (1) to the base on the wall.
3
EN
20 mA
20 mA
50 mA
with E46ADCN/E49
250 mA
Two wire
2.0 – 7.2 Ah
15 min
105 dB(A) at 1 m.
1500 Hz
LED
60
2.1 Kg
IP44
(-25) – (+55) °C
YES
IK08
Secondary battery
7 Ah (*)
7 Ah (*)
2 Ah

Publicidad

loading

Este manual también es adecuado para:

0 844 25