Descargar Imprimir esta página

Finder 10.41.8.120.0000 Manual De Instrucciones página 2

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
EN60669-1 / EN60669-2-1
10.41.8.120.0000
U
120 V AC (50/60 Hz)
N
U
: 96 V AC
min
www.findernet.com
U
: 132 V AC
max
P: 2 VA
10.41
1NO (SPST- NO)
16 A 120 V AC μ
AC1 1900 VA
AC15 400 VA
(120V AC) 1000 W
(120V AC) 400 W
(–30...+70)°C
T
= 15s
ON
T
= 30s
OFF
8mm > 15 mm
(1x6 / 2x4) mm
0.8 Nm
(1x10 / 2x12) AWG
IB1041001 - 01/13
10.41.8.230.0000
U
230 V AC (50/60 Hz)
N
U
: 184 V AC
min
U
: 253 V AC
max
P: 2 VA
1NO (SPST- NO)
16 A 230 V AC μ
AC1 3700 VA
AC15 750 VA
AC5a
5A
(230V AC) 2000 W
(230V AC) 750 W
IP54
0,8 Nm
2
(1x6 /2x2.5) mm
2
(1x10 /2x14) AWG
1
2
3
3a
4
5
A - B
ENGLISH
10.41
LIGHT DEPENDENT RELAY
It is recommended to install the relay such that the light emitted
from the controlled lamp(s) does not influence the sensor. Where
this is not possible, the innovative "light feedback compensation"
principle will avoid annoying lamp switch-on and switch-off, provided
that the sum of ambient light and controlled light does not exceed
120 lux. Ensure that the cable compression gland is tightened to
achieve IP54 sealing.
1
POLE MOUNTING
2
WALL MOUNTING
3
WIRING DIAGRAM
Only the live of the load circuit is interrupted, between terminals L
and L1. Terminals N and N1 have been provided to aid installation,
but they are internally linked.
Make the electrical connections according to the diagram, ensuring
that the cable gland is tightened around the cable.
Cable type suggested: H07RN–F (2x1 mm
2
...2x2,5 mm
Important Safety Advice: if the lamp has a ground wire terminal,
it is necessary to connect it to the protective earth system before
activation.
3a
Internal connections
4
SETTINGS
A: ambient light threshold (1...80)lx
B: LED (behind the transparent adjustment knob):
- slow blinking: supply ON, relay OFF
- fast blinking: supply ON, timing in progress, relay OFF
- continuous: supply ON, relay ON
5
TESTING
Over the first 3 working cycles the On and Off delay times are
reduced to zero in order to aid installation.
The packaging can be used to darken the photocell in order
to test or regulate the relay.
2
) or similar.

Publicidad

loading

Este manual también es adecuado para:

10.41.8.230.0000