Descargar Imprimir esta página

Firstech, LLC. FTI-GMT3 Notas De Instalación Y Configuración página 3

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALL GUIDE
Page 58 of 59
1
1
2
3
ON
4
5
OFF
6
7
8
9
ON
10
11
OFF
WWW.IDATALINK.COM
Patent No. US 8,856,780 CA 2759622
COM-BLADE-AL(DL)-GM12-EN
CARTRIDGE INSTALLATION
Slide cartridge into unit. Notice
button under LED.
MODULE PROGRAMMING PROCEDURE - WITH KLON
Close driver door.
Re-open driver door to wake up
data bus.
Insert key into ignition.
Turn key to ON position.
Wait, LED will turn solid RED.
Turn key to OFF position.
Remove key.
LED will turn OFF.
Insert key into ignition.
Turn key to ON position.
Wait, LED will fl ash BLUE
rapidly.
Turn key to OFF position.
2
12
13
 
14
15
16
17
ON
18
19
OFF
20
DOORLOCK INTERFACE
GENERAL MOTORS
Doc. No.: ##74801##
20210312
Ready for Module Programming
Procedure.
Remove key.
WARNING:
Disconnect power last.
Disconnect module from vehicle.
Connect module to computer
and proceed with extended
programming.
WARNING: Do not press module
programming button.
Connect power fi rst.
Connect module to vehicle.
Close driver door.
Re-open driver door to wake up
data bus.
Turn key to ON position.
Wait, LED will turn solid BLUE
for 2 seconds.
Turn key to OFF position.
Module Programming
Procedure completed.
Automotive Data Solutions Inc. © 2020

Publicidad

loading