Simu T3.5 Manual Del Usuario página 8

Ocultar thumbs Ver también para T3.5:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
Re-adjustement of end limits
8
8.1 : Re-adjustement of UP end limits
1- Position the motor on the UP end limit previously
set in §4.3b with the UP key.
2- Press simultaneously for 5 seconds the UP and
DOWN keys, The motor will run for a half a second
in one direction and then in the other direction.
3- Adjust the new position with the UP and DOWN
keys.
4- Validate the new position by pressing 2 seconds
the STOP key. The motor will run for a half a
second in one direction and then in the other
direction. The new end limits setting is memorized.
8.2 : Re-adjustement of DOWN end limits
1- Position the motor on the DOWN end limit pre-
viously set in §4.3a with the DOWN key.
2- Press simultaneously for 5 secondes the UP and
DOWN keys, The motor will run for a half a second
in one direction and then in the other direction.
3- Adjust the new position with the UP and DOWN
keys.
4- Validate the new position by pressing 2 seconds
the STOP key. The motor will run for a half a
second in one direction and then in the other
direction. The new end limits setting is memorized.
Cancelling programming and settings
9
9.1
- Switch off the power supply to the motor for 2 seconds.
- Switch on the power supply to the motor for 7 seconds.
- Switch off the power supply to the motor for 2 seconds.
- Switch the power to the motor back on. The
motor will run for 5 seconds in random direction
and is now in the "cancelling" mode.
If you switch off the power to several motors, they will all be in cancelling mode. That is why,
you must "eject" out of this mode all the receivers that are not to be deprogrammed by sending
a command from their individual control transmitter (UP or Down).
9.2 - Then, validate the cancelling of the affected motor from the individual control:
- Press the "PROG" key of the transmitter more
than 7 seconds. Maintain the pressure until the
motor will first run for a half a second in one
direction and then the other, and a few second
later, it will run again in both direction.
The Hz.02 motor is now as it was originally configured, and no transmitter and no settings is saved
in its memory and is ready for a new programming.
Hereby, SIMU, declares that this equipment "T3.5Hz.02" is in compliance with the essential requirements and
other relevant provision of Directive 1999/5/EC. A declaration of Conformity is available at the web address:
www.simu.fr, heading "Normes". Usable in EU,
1
2
1
2
OFF
ON
2s
7s
>>
PROG 7s
3
5s
3
5s
5s
OFF
2s
>>
2s
7s
4
2s
4
2s
5s
ON
4 / 4

Publicidad

Tabla de contenido
loading

Tabla de contenido