Electrical Safety - DeWalt D25840 Manual De Instrucciones

Ocultar thumbs Ver también para D25840:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
E N G L I S H
– minimised break-out when chiselling or drilling in
soft or brittle materials
– optimal tool control for precise chiselling
Service indicator LEDs
The yellow brushwear indicator LED (4) lights up
when the carbon brushes are nearly worn out to
indicate that the tool needs servicing within the next
8 hours of use. The red service indicator LED (3)
lights up if there is a fault with the tool or the brushes
have completely worn out.
Fully vibration-dampened main handle
The dampers in the main handle (9) absorb the
vibrations transmitted to the user. This improves
user comfort during the operation.

Electrical safety

The electric motor has been designed for one
voltage only. Always check that the power supply
corresponds to the voltage on the rating plate.
Your D
WALT tool is double insulated in
E
accordance with EN 60745; therefore no
earth wire is required.
Mains plug replacement
(U.K. & Ireland only)
• Should your mains plug need replacing and you
are competent to do this, proceed as instructed
below. If you are in doubt, contact an authorized
D
WALT repair agent or a qualified electrician.
E
• Disconnect the plug from the supply.
• Cut off the plug and dispose of it safely; a plug
with bared copper conductors is dangerous if
engaged in a live socket outlet.
• Only fit 13 Amperes BS1363A approved plugs
fitted with the correctly rated fuse (1).
• The cable wire colours, or a letter, will be marked
at the connection points of most good quality
plugs. Attach the wires to their respective points
in the plug (see below). Brown is for Live (L) (2)
and Blue is for Neutral (N) (4).
• Before replacing the top cover of the mains plug
ensure that the cable restraint (3) is holding the
outer sheath of the cable firmly and that the two
leads are correctly fixed at the terminal screws.
24
Never use a light socket.
Never connect the live (L) or neutral (N)
wires to the earth pin marked E or
For 115 V units with a power rating exceeding 1500 W,
we recommend to fit a plug to BS4343 standard.
Using an extension cable
If an extension cable is required, use an approved
extension cable suitable for the power input of this
tool (see technical data). The minimum conductor
size is 1.5 mm
2
.
When using a cable reel, always unwind the cable
completely.
Also refer to the table below.
Conductor size (mm
2
)
0.75
1.00
1.50
2.50
4.00
Voltage
Amperes
115
0 - 2.0
2.1 - 3.4
3.5 - 5.0
5.1 - 7.0
7.1 - 12.0
12.1 - 20.0
230
0 - 2.0
2.1 - 3.4
3.5 - 5.0
5.1 - 7.0
7.1 - 12.0
12.1 - 20.0
Cable rating (Amperes)
6
10
15
20
25
Cable length (m)
7.5
15
25
30
45
Cable rating (Amperes)
6
6
6
6
6
6
6
6
15
6
6
10
15
20
10
10
15
20
20
15
15
20
25
25
20
20
25
-
6
6
6
6
6
6
6
6
6
6
6
6
10
10
10
10
10
15
15
15
15
15
20
20
20
20
20
25
.
60
6
10
15
20
25
-
-
-
6
6
6
6
15
15
20
-

Publicidad

Tabla de contenido
loading

Tabla de contenido