2 - Air dump instructions:
There are numerous ways of dumping air from your BC.
The choice of air dump method depends on the diver's
situation during the course of the dive and the degree
of urgency needed to control buoyancy.
All of the purge valves installed on models in the
Beuchat product range are overpressure relief valves;
therefore they prevent all risk of bursting due to over-
inflation or uncontrolled ascent.
A > S S l l o o w w d d e e f f l l a a t t i i o o n n : integrated in the power
inflator.
This procedure is done preferably in an upright position
(see figure 18).
•Take the power inflator in your left hand.
•Raise the inflator.
•To deflate, press the button at the inflator's end.
The buoyancy adjustment obtained during this
procedure is very precise.
Use / Instructions for use > 43
B > U U p p p p e e r r e e x x h h a a u u s s t t v v a a l l v v e e : found on the right
shoulder.
This procedure allows for a very fast air dump, from a
horizontal or vertical position (see figure 18).
•Take the dump valve in your right hand.
•Pull, but not excessively, toward the bottom of the BC.