Application
Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters
(displacement water heaters) is not possible.
Specifications
• Max. flow
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
• Water connection
• Deck thickness max.
Notes:
- Major pressure differences between cold and hot
water supply should be avoided.
- To be installed according to local codes and
regulations.
Installation
Refer to the dimensional drawing on page 1.
Flush pipes thoroughly!
Fit spout, see fig. [1].
Insert swivel spout (A) and secure with clip (B).
Mount faucet on basin, see fig. [2].
1. Place seal (C) on basin and insert faucet through the
holes of the basin.
2. Screw on counter nut (D) from below and tighten
with an 27mm open-ended wrench.
3. Close the headparts (clockwise for the hot side and
counter-clockwise for the cold side).
8.3 L/min o 2.2 gpm / 60 psi
7.25 psi
14.5 - 72.5 psi
145 psi
232 psi
176 °F
cold - Right hand
hot - Left hand
2 3/16"
English
Connect faucet, see fig. [2].
For this purpose the supply must be connected to the
angle stops (or other supply points).
The cold water supply should be connected on the
right, the hot water supply on the left side.
Mount lever (18 173), sold separately, see fig. [3].
1. Push on lever (E).
2. Screw the brass nut (E1) into the cap until tight.
Hand tighten only!
3. Tighten with screw (F) and screw in cover cap (G).
It is recommended that the lever (E) be installed so
they point away from the spout when in the off position.
Open cold and hot water supply and check
connections for watertightness!
Maintenance
Inspect and clean all parts, replace as necessary and
grease with special grease.
Shut off the hot and cold water supply!
I. Ceramic headpart, see fig. [4].
1. Unscrew cover cap (G) and screw out screw (F).
2. Unscrew brass nut (E1) and pull off lever (E).
3. Unscrew cap (H).
4. Unscrew ceramic headpart (J) using a 17mm socket
wrench.
5. Change complete ceramic headpart (J).
Observe the different replacement part numbers of
the headparts, see page 2.
Observe the correct installation position!
II. Flow regulator, see page 2.
Unscrew and clean flow regulator (13 955).
Assemble in reverse order.
Replacement parts, see page 2 ( * = special
accessories).
Care
Instructions for care of this faucet will be found in the
Limited Warranty supplement.