16
1. Connect a battery charger to the vehicle.
2. With the wiTECH diagnostic application, perform the following steps:
Select "RADIO FREQUENCY HUB MODULE (RFHM)"
Turn the ignition to the off/lock position. The ignition must be left off throughout this procedure on
vehicles equipped with the RFHub.
Select the "MISCELLANEOUS FUNCTIONS" tab
Highlight "PROGRAM IGNITION FOBIKs"
Select "CONTINUE"
Note OnScreen instructions and select the "FINISH" button
Cycle ignition key after the successful routine completion.
1. Connect a battery charger to the vehicle.
2. With the wiTECH diagnostic application, perform the following steps:
3. Turn the ignition ON.
Select "RADIO FREQUENCY HUB MODULE(RFHm)"
Select the "MISCELLANEOUS FUNCTIONS" tab
Highlight "RFHUB REPLACE"
Select the "Start Misc Function" button
Select "NEXT"
Enter the PIN when prompted.
Select "NEXT"
Verify that the PIN number is correct
Once verified select "NEXT"
Select "NEXT"
Note OnScreen instructions and select the "CLOSE" button
Cycle ignition key after the successful routine completion