MODE
Auto mode - Continuously drying mode – Sleeping mode cycle, press once to
switch the mode from one to another, the corresponding indicator lights up.
Auto mode: when environmental humidity ≥ set humidity 3%, the fan starts working and
compressor starts working after 3 seconds. When environmental humidity ≤ set
humidity -3%, the compressor stops working and fan stops working after 30 seconds'
delay. Both fan speed and humidity can be adjusted under auto mode.
Continuously drying mode: The machine continues to run, but the humidity cannot be
adjusted.
Sleeping mode: Touch the sleep button, the button lights up and start the sleep
function. After no operation in 10 seconds, all indicators turns dark gradually and the
wind speed is automatically switched from high to low. Touch any button to wake up the
indicator. Touch sleep button again to exit the sleep mode. In sleep mode, the fault code
is not displayed, the wind speed is not adjustable, and the humidity is adjustable.
TIMER
Press this key to set the timer function of 0-24 hours. The interval is 1 hour. Each time you
press this button, the value increased 1 hours and then the corresponding timing value is
displayed on the screen. The setting value is "00" to cancel the timer function. The indicator
turns out.
After the timer is set and completed, the timer LED is on during the timing period. After the
timing is over, the timer LED turns off automatically.
In the running state, set the time to turn off the machine;
in the standby state, set the time to turn on the machine.
HUMIDITY SET
In automatic mode or sleep mode, you can operate this key to adjust the set humidity: every
time you press the set humidity increase by 5%, according to the cycle of
30%-80%. Long press this key to query the current room temperature, double eight lights
display the current room temperature 5 seconds after the automatic return to display the
current humidity. If this key is pressed for a long time, it will be display the ambient
temperature.
FAN SPEED (SPEED)
The wind speed can only be adjusted in the automatic mode. Press this key to switch the
high and low wind speed. The corresponding wind speed indicator lights up.
12