Página 1
Information furnished by EXLAR Corporation is believed to be accurate and reliable. However, no responsibility is assumed by EXLAR Corporation for its use. EXLAR reserves the right to change the design and operation of the equipment described herein and any associated motion products that may appear in this document. Information in this document pertaining to equipment not furnished by EXLAR should be confirmed by that equipment manufacturer.
Página 2
(see Terms and Conditions above), provided, however, that written notice of claimed defects shall have been given to Exlar within thirty (30) days from the date of any such defect is first discovered. The product(s) claimed to be defective must be returned to Exlar, transportation prepaid by Buyer, with written specification of the claimed defect.
Página 3
Exlar be liable under this warranty otherwise for special, incidental or consequential damages, whether similar or dissimilar, of any nature arising or resulting from the purchase, installation, removal, repair, operation, use or breakdown of the product(s) or any other cause whatsoever, including negligence.
Digital I/O ..................................50 4-20 mA Analog Input ............................... 52 4-20 mA Analog Outputs ..............................53 Serial Communications Port.............................. 54 Declaration of Conformity ..............Error! Bookmark not defined. Product Marking ..........................56 EXP 24 Manual 1/9/14 PN 47676 Exlar Corporation Revision H 952-500-6200...
As with any electro-mechanical device, safety must be considered during the installation and operation of the actuator and controller. Throughout this manual you will see paragraphs marked with CAUTION and WARNING signs as shown below. WARNING EXP 24 Manual 1/9/14 PN 47676 Exlar Corporation Revision H 952-500-6200...
Página 27
опасни местоположения. Всяко допълнително оборудване, използвано за инсталиране на уредитем като кабели, кабелни уплътнения, предпазители и т.н., и техниките за инсталиране трябва да отговарят на локалните кодове за употреба на опасни местоположения. EXP 24 Manual 1/9/14 PN 47676 Exlar Corporation Revision H 952-500-6200...
Manufactured by Exlar Corporation. For Actuator / Motor installation refer to the corresponding manual, for example EL100 Actuator Installation manual, Exlar PN 44465. Application The EXP-24 is designed to meet general industrial motion control requirements for high temperature hazardous locations. Typical applications include gas turbine guide vane and valve motion control. General Specifications The controller is designed to be used specifically with the EL100 Actuator but can be used to drive most three phase linear actuators and rotary motors with similar ratings.
D = Vent and Drain Selection D = Drain Only V = Vent Only B = Both (Drain and Vent) EEE = Customer Code FFFFF = Part Number Identification label Typical Label EXP 24 Manual 1/9/14 PN 47676 Exlar Corporation Revision H 952-500-6200...
Página 34
17 ft-lbs (23 Nm) efter en elektrisk installation för att bibehålla ordentlig försegling vid drift i farliga miljöer. Actuator / Motor Actuator / Motor Feedback Port Power Port PLC I-O Ports 24 V Incoming Power Port Mounting Dimensions EXP 24 Manual 1/9/14 PN 47676 Exlar Corporation Revision H 952-500-6200...
Digital Output 1 Digital Output 2 Common 4-20mA Analog Output 1 4-20mA Analog Output 2 Modbus RS 485 Port Motor Power R,S,T & PE Motor Term Resolver Feedback System Overview EXP 24 Manual 1/9/14 PN 47676 Exlar Corporation Revision H 952-500-6200...
EXP Controller and the Actuator/ Motor must not exceed 20 feet in length. 20 ft. max Motor power cable 24 V dc Input Power Actuator / EXP 24 Motor Controller Motor feedback cable Controller I-O PE Connection Wiring Overview Grounding WARNING EXP 24 Manual 1/9/14 PN 47676 Exlar Corporation Revision H 952-500-6200...
/ exit point. This is most easily accomplished with EMC type cable glands that provide 360° contact between the shell and shield. Tape or heat shrink applied to cable end EXP 24 Manual 1/9/14 PN 47676 Exlar Corporation Revision H 952-500-6200...
ANALOG OUT 2 – 5 J3 24 V DC RETURN 24 V DC RETURN 24 VDC + 24 VDC + Controller Wiring Table, Attached to Interior of Controller Cover EXP 24 Manual 1/9/14 PN 47676 Exlar Corporation Revision H 952-500-6200...
20 ft. max EXP 24 Controller R Actuator / Motor Shield Function Terminal Motor R Phase Motor S Phase Motor T Phase Motor PE EXP 24 Manual 1/9/14 PN 47676 Exlar Corporation Revision H 952-500-6200...
Function Terminal Function Terminal Cos Shield Ref Shield Cos Low Ref Low Cos High Ref High Sin Shield ACT Temp Shied Sin Low ACT Temp Sin High ACT Temp EXP 24 Manual 1/9/14 PN 47676 Exlar Corporation Revision H 952-500-6200...
I/O must be supplied by an external 24 V DC supply. The functions of the I/O are fully programmable and setup on the I-O page of the Expert Software Inputs The EXP-24 provides two digital inputs, Input 1 and Input 2, each input consists of a signal line and a return line. Function...
Página 51
500 V DC + 24 V Exp 24 Isolated Output Circuit Typical PLC Input Circuit Output 1 or 2 Power Output 1 or 2 Signal Common Digital Output Circuit EXP 24 Manual 1/9/14 PN 47676 Exlar Corporation Revision H 952-500-6200...
12 bit (4096) Linearity +/- 1 % over 20mA Typical PLC with Isolated 4-20 mA Analog Output Exp 24 non-isolated 4-20mA Analog Input Circuit 4-20 mA Analog Input Circuit EXP 24 Manual 1/9/14 PN 47676 Exlar Corporation Revision H 952-500-6200...
+/- 1% of 20mA Isolation from PE and Supply 500 V Exp 24 Isolated 4-20mA Analog Output Circuit Typical PLC 4-20 mA Analog Input 4-20 mA Analog Output Circuit EXP 24 Manual 1/9/14 PN 47676 Exlar Corporation Revision H 952-500-6200...
Serial Data A (TX -) Serial Data B (TX +) Serial Data Common Serial Data Term Resistor Typical Host or 485 Converter EXP 24 Isolated RS 485 Circuit Serial Communication RS 485 Circuit EXP 24 Manual 1/9/14 PN 47676 Exlar Corporation Revision H 952-500-6200...
Ex II 2 G Ex d IIB T5 Gb 0081 LCIE 09 ATEX 3057 X English 17 Special Conditions for Safe Use (Denoted by X after Certificate Number) Operating Ambient Temperature: -29°C to +82°C EXP 24 Manual 1/9/14 PN 47676 Exlar Corporation Revision H 952-500-6200...