Open-Ended Systems With Direct Water Supply; Service; Periodic Maintenance; Repair - Danfoss APP 5.1 Instrucciones

Ocultar thumbs Ver también para APP 5.1:
Tabla de contenido

Publicidad

Instruction
6.

Service

8
APP pump instruction APP 5.1-10.2
5.5.2 Open-ended systems with direct water
supply
1.
Disconnect the water supply to the pump.
2.
Through the lower bleeding plug, empty
the pump housing of water and close it
again.
3.
Connect the pump to a tank of e.g. 25 litre/
6 gal. of anti-freeze additive. Connect a

6.1 Periodic maintenance

The APP pump is designed so that lubrication
follows from the water itself and there is thus no
oil in the pump.
The pump requires no periodic replacements of
seals and valve parts.
180R9072 / 521B0747 / DKCFN.PI.010.D4.02 / 10.2012
hose to the inlet port of the pump and via
another hose return the flow from the
outlet port to the tank with anti-freeze
additives.
4.
Quickly start and stop the pump.
Make sure that the pump does not run
dry. The pump is now protected against
internal corrosion and frost.

6.2 Repair

In case of irregular function in the pump, please
contact the Danfoss Sales Organisation.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

App 10.2

Tabla de contenido