NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
ELECTRICAL PRECAUTIONS
DOUBLE INSULATION
Double insulated products do not need to be grounded. Three-wire
grounded power cord is not required for safe operation. All exposed metal
parts are isolated from the internal metal motor and chassis.
WARNING: The double insulated system is intended to protect the user
from shock resulting from a break in the product's internal wiring. Observe
all normal safety precautions to avoid electrical shock.
NOTE: Servicing of a product with double insulation requires extreme care
and knowledge of the system and should be performed only by a qualified
service technician. For service, we suggest you return the product to your
nearest authorized service center for repair. Always use original factory
replacement parts when servicing.

ELECTRICAL CONNECTION

This product should be connected to a power supply that is 120 volts, AC
only (normal household current), 60 Hz. Do not operate this product on
direct current (DC) through the power cord. A substantial voltage drop will
cause a loss of power and the motor will overheat. If the product does not
operate when plugged into an outlet, double-check the power supply.

EXTENSION CORDS

When using a product at a considerable distance from a power source, be
sure to use an extension cord that has the capacity to handle the current
the product will draw. An undersized cord will cause a drop in line voltage,
resulting in overheating and loss of power. Use the chart to determine the
minimum wire size required in an extension cord. Only round jacketed
cords listed by Underwriter's Laboratories (UL) should be used.
When using this product outdoors, use an extension cord that is designed
for outside use. This type of cord is designated with "WA" or "W" on the
cord's jacket.
Before using any extension cord, inspect it for loose or exposed wires and
cuts or worn insulation.
**Ampere rating (on product data plate)
Amperes
0‑2.0
2.1‑3.4
(A)
Cord
Size Wire: American Wire Guage (AWG)
Length
25 ft
16
16
50 ft
16
16
100 ft
16
16
** Used on 12 gauge - 20 amp circuit
WARNING: Keep the extension cord clear of the working area. Posi-
tion the cord so that it will not get caught on lumber, tools, or other obstruc-
tions while you are working with this product. Failure to do so can result in
serious personal injury.
WARNING: Check extension cords before each use. If damaged
replace immediately. Never use a product with a damaged cord since
touching the damaged area could cause electrical shock resulting in serious
injury.
WARNING: To reduce the risk of electrical shock, use only with an
extension cord intended for outdoor use, such as an extension cord of
cord type SW-A, SOW-A, STW-A, STOW-A, SJW-A, SJOW-A, SJTW-A, or
SJTOW-A.
10
3.5‑5.0
5.1‑7.0
7.1‑12.0
12.1‑16.0
16
16
14
16
14
14
14
12
10
14
12