NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
Specifications
MODEL:
BURN RATE:
SUPPLY PRESSURE TO REGULATOR:
REGULATOR PRESSURE:
MANIFOLD PRESSURE:
FUEL RATE:
FUEL ORIFICE PORT SIZE:
FAN RATING:
ELECTRICAL INPUT:
IGNITION:
PRIMARY FLAME CONTROL:
HIGH TEMPERATURE CONTROL:
WARNING: CERTIFIED FOR USE WITH PROPANE ONLY
WARNING: CERTIFIED FOR USE WITH DEWALT RECHARGEABLE BATTERY
PACKS REFER TO CHART BELOW A LIST OF APPROVED BATTERIES
Approved Battery Packs
20V MAX*
Size
Run Time**
1.3Ah
2 hours
1.5Ah
2.5 hours
2.0Ah
3.2 hours
3.0Ah
5 hours
4.0Ah
6.5 hours
5.0Ah
8.3 hours
6.0Ah
10 hours
DXH70CFAV
27,000-68,000 BTU/hr
MAX: 200 psi (1380 kPa) MIN. 20 psi (137.9 kPa)
20 psi (137.9 kPa)
20 psi (137.9 kPa)
3.24#/hr (1.47 kg/hr)
0.94mm
135 cfm
20 Vdc / .6A or 120 VAC
Auto Spark/ Manual Gas Valve
Thermocouple Operated Gas Valve
221°F (105°C)
FLEXVOLT®
Size
Run Time**
6.0Ah
10 hours
9.0Ah
15 hours
All run times are approximate. Actual run
times may vary. State of charge, battery
temperature and battery age will all affect
actual runtime
* Maximum initial battery voltage (measured
without a workload) is 20 volts. Nominal
voltage is 18.
**Calculation assuming 73°F (23°C) ambient
temp battery pack
CONTENTS
WARNINGS
HEATER SPECIFICATIONS
OPERATING PRECAUTIONS
SAFETY PRECAUTIONS
PREPARING FOR OPERATION
SERVICING
PROPANE TANK SIZING
WIRING SCHEMATIC
ELECTRICAL PRECAUTIONS
CHARGING PRECAUTIONS
BATTERY PRECAUTIONS
CHARGER OPERATION
WARRANTY BATTERY /CHARGERS
EXPLODED VIEW
PARTS LIST
MINIMUM CLEARANCE: From normal combustible material
Clearance
From Floor. ................................................................................ 0 t (0 M)
From outlet ............................................................................ 6 ft (1.8 M)
From Sides ............................................................................ 4 ft (1.2 M)
From top ............................................................................... 6 ft (1.8 M)
Locate 10' (2.4 M) from canvas or plastic tarpaulins or similar coverings and
secure them to prevent flapping or movement due to wind action.
4
2
4
5
5
7
8
8
9
10
10
11
13
15
16
17