8. Optional Components
8.1 The thermostatic circulation bridge
The thermostatic circulation bridge ensures the delay-free provision of the heating medium for hot water preparation.
The supply temperature can be adjusted progressively, using the temperature scale of 35 - 65 °C .
Adjust the value by screwing or unscrewing spindle „Z" using a flat spanner (WF size 11 mm).
8.2 Service water circulation pump set (optional)
The circulation pump set, consisting of a circulation pump and timer with a programmable weekly programme, is used for the delay-free
provision of hot water at the tap-off fitting where there are very long connection pipes.
When using a circulation pump set, no additional thermostatic circulation bridge is necessary.
LogoVital 35 kW (10231.35 WWB) with circulation pump set
(10252.44)
20
LogoVital 46 kW (10231.41 WWB) circulation pump set
(10252.45)