REAR PANEL
All inverters described in this manual have two terminals for connecting battery
cables. One terminal is the Positive (+) terminal [red]; the other is the Negative (−)
terminal [black]. The Positive battery cable should have a Battery Protection Fuse
installed within one foot of the battery connection. The negative cable can be
directly attached to the negative battery terminal. In some cases, a metal vehicle
frame can be used as part of the negative cable to the battery.
High Speed Fan – The fan turns on when there is a high load or an elevated
temperature to keep the inverter cool. Do not block. Keep 2-inch clearance.
Ground Terminal – This terminal is for attaching a 12 gauge insulated safety
ground wire. This safety wire protects personnel if there is an unlikely failure in
either the cabling or enclosure insulation. Do not directly connect this ground to
the negative DC terminal on the inverter. This safety wire is to be connected to
the vehicle frame or earth ground or negative battery terminal as described in the
installation procedure.