7
7D
7B
7 TEMPERATURE KNOB ATTACHMENT
Lubricate the Cartridge O-Rings (7A) using provided Grease. Insert Knob
Assembly (7B) into Valve Body (7C) aligning the Cartridge Hole (7D) with
Valve Hole (7E). Secure Knob Assembly (7B) using Set Screw (7F).
Caution: Do not over tighten!
8 UNIT START UP
Turn on hot and cold water supplies, and check all connections for leaks.
9
9A
FULL HOT
9 VALVE FUNCTION
By rotating Temperature Knob (9A) clockwise, the water temperature will
decrease to fully cold. The water temperature can be increased by rotating
Temperature Knob (9A) counterclockwise.
The Temperature Knob (9A) is regulated for the water temperature not to to
exceed 100°F (38°C) to prevent burns. To increase the water temperature,
press Button (9B) and rotate the Temperature Knob (9A) in the counterclockwise
direction.
10
10C
10F
10E
7C
7E
7A
7F
9B
FULL COLD
10D
10A
10G
10B
ENGLISH
TROUBLE SHOOTING TIPS
• Temperature or Flow does not remain constant
The Cartridge Assembly (10A) must be cleaned. Shut-off water supply.
Remove Set Screw (10B), and Knob Assembly (10C) from Valve Body (10D).
Inspect inlets for sediment and flush with water. Inspect O-Rings (10G) for
damage. Re-install Cartridge Assembly (10A), and turn on water supply. If
problem persists replace Cartridge Assembly (10A).
CAUTION: Do not disassemble Cartridge (10A).
• Dripping from either the tub spout or shower head.
Clean the Cartridge Assembly (10A). Check to ensure the two Oval O-Rings
(10G) on Cartridge (10A) are in place. Reassemble cartridge, and trim
assembly and handle. Turn on the water and test. If the unit still leaks, replace
the Cartridge.
• Make sure that both hot and cold water inlets are turned on.
• Water flow is very low.
Check the Cartridge Assembly (10A), for debris. Sediment where the water
enters the Shower Head can also cause this symptom.
• Water starts out cold and becomes hotter as handle is rotated clockwise.
This is a potentially hazardous situation and should be corrected before using
the unit. Check the hot and cold inlet positions (hot-left, cold-right).
• Water flows from the tub spout while using the shower.
The seal inside of the diverter mechanism may have become dislodged. The
Spout may need replacement.
MAINTENANCE & CARE
CAUTION: Maintenance
DISASSEMBLY
1.
Replacement parts may be available at the store where you purchased
your faucet.
2.
When replacement parts are not available, please write or call Price
Pfister Consumer Service.
3.
Always turn off water and relieve pressure before working on your
faucet.
NOTE: Trim Care
Cleaning Instructions:
For all Handles and decorative finishes, use only a soft damp cloth to clean
and shine. Use of polish, detergents, abrasive cleaners, organic solvents or
acid may cause damage. Use of other than a soft damp cloth will nullify
our warranty!
Special Trim:
Trim products which contain Porcelain or other similar substance are not
acceptable for public areas or Commercial use. Installation of Said Trim is
at Users Risk!