Universal mount:
The laser receiver RX 51 can be fitted on measuring staffs
with the universal mount. The Flexi measuring staff (Art. No.
080.50) is always recommended when measuring from floor
heights. It also allows you to determine heights directly
without any need for calculation.
Note: Always switch the unit off before moving it (pushbutton 11, status
indicator 10 off) in order to protect it against damage.

Technical data

Self-levelling range
Precision
Working range with laser receiver
Laser wavelenghts, line lasers / plumb laser
Laser class / Laser output rating line lasers
Laser class / Laser output rating plumb laser
Protection class PCL 5P RXR
Power supply PCL 5P RXR (batteries)
Power supply PCL 5P RXR (rechargeable batteries)
Operating period (rechargeable NiMH)
Power supply laser receiver RX 51
Power supply for remote control
Weight PCL 5P RXR
Operating temperature
Storage temperature
Order number
Subject to technical alterations
Note: Regularly check the calibration before use, after transport and after
extended periods of storage.
PrecisionCross-Laser PCL 5P RXR
ENGLISH
+ 3°
+ 1 mm / 10 m
max. 50 m
635 nm / 655 nm
2M / < 5 mW
2 / < 1 mW
IP 54
4 x 1,5V LR6 (AA)
4 x 1,2V R6 NiMH (AA)
ca. 8 h
1 x 9V block
2 x 1,5V LR 03 (AAA)
1,7 kg
0°C ... + 50°C
-10°C ... + 70°C
039.00.00A
01/2008