LEDS COLOR CODE
1. Red
2. Green
3. Yellow
4. Blue
The battery pack and the battery charger
are delivered in separate boxes. Please
ensure you have well received these
boxes and check the contents.
INSTALLATION
● Insert the battery pack.
There is no ON/OFF switch: the tool is ready
to operate as soon as a loaded battery pack
is mounted.
● Unplug the battery pack when the tool
is not used.
● Do not leave the battery pack on the
charger when the charger power supply
is off.
SET UP
See page 7.
1. Plant network
2. Ethernet link
3. Battery nutrunner
● Check you have the following equipment:
LRTBC battery nutrunner
(firmware version 5.00.00.X
or higher)
CVI3 Vision controller
(firmware version 1.5.2.0 or
higher)
Desoutter Wi-Fi access point + power cord
Ethernet network
Ethernet cable (not supplied) to connect the Wi-
Fi access point to the controller
Standard PC connected to the Ethernet network
and equipped with the Desoutter CVI3 Suite
software to create and control the tightening
processes
● Before starting the set up, check that you
have the following information on hand.
06/2019
+ battery
+ charger
+ e-DOCK device
to connect the
tool to the PC
+ power cable
15 / 156
Device
Parameters
IP address
Network name
Wi-Fi
(SSID)
access
Security type
point
Encryption type AES/CCMP
security key
Battery
IP address
nutrunner
IP address
Controller
Communication
port
The controller IP address, subnet
mask and communication port must
be identical in the controller and the
battery nutrunner settings.
● Check with your local Desoutter
representative how to set up your
specific system environment.
● To get the complete list of the
configuration by default, refer
to the CVIMONITOR user
manual at http://resource-center.
desouttertools.com.
Wi-Fi access point
● Contact your local Desoutter representative
for more information.
Battery nutrunner
When delivered, all battery nutrunners
are set with the same communication
parameters.
● Change the battery nutrunner IP
address and the communication port
to avoid settings issues.
● Insert the battery pack and plug the e-DOCK
as shown page 8.
● Connect the e-DOCK to the PC USB port. A
new serial port is created.
● Launch CVIMONITOR software and select
"Tool" tab on the top of the screen.
● Change the parameters according to your
installation.
Controller
● To install and power on the controller, follow
the instructions listed in the Quick-start user
manual 6159932290 supplied in the controller
box.
● Connect the controller to the
Ethernet network by plugging the
Ethernet cable into port 1 located
on the controller bottom panel.
6159924630_04
by default
192.168.5.201
Desoutter_1
WPA/WPA2PSK
mydesoutter_1
192.168.5.221
192.168.5.212
7477