until
is indicated on the display . Then the
unit returns to normal operation .
3) Adjust the sensitivity in such a way that an
optimum volume level of the microphone is
reached . If the volume is too high, the micro
phone will distort, then adjust a lower value
with the key (9) . If the volume is too low,
a poor signalnoise ratio will result, then ad
just a higher value with the key (10) .
4) Save the adjustment by pressing the key
SET . The display shortly indicates
the adjusting mode is exited, the unit re
turns to normal operation .
5.3 Locking / unlocking the unit
With the unit locked, it is not possible
a) to switch off the unit; if the power switch (4)
is set to OFF with the unit locked, the display
shows
.
b) to call up the adjusting modes for frequency
and sensitivity .
5.3.1 Activating the lock function
1) First call up the frequency adjusting mode:
Keep the key SET (8) pressed for 2 s .
2) As soon as MHZ flashes on the display,
shortly press the button SET to go to the
sensitivity adjusting mode .
3) As soon as the display indicates the sensitiv
ity, shortly press the key SET to go to the
lock mode:
(locking deactivated) .
4) Press the key (10):
display .
5) Save the adjustment by pressing the key
SET .
is shortly displayed, the adjusting
mode is exited, the unit returns to normal
operation .
5.3.2 Deactivating the lock function
1) The power switch (4) must be set to ON .
2) Keep the key SET (8) pressed for 3 s until
flashes on the display .
3) Press the key (9):
display .
4) Save the adjustment by pressing the key
SET .
is shortly displayed, the adjusting
mode is exited, the unit returns to normal
operation .
flashes in the display
flashes on the
flashes on the
6 Replacement
Microphone Cartridge
The dynamic microphone cartridge (1) can be
replaced by the condenser microphone car
tridge MD872 (order no . 23 .3440) which is
supercardioid and has an extended frequency
range (50 – 18 000 Hz) .
7 Specifications
Type of unit: . . . . . . . . dynamic handheld
,
Directivity: . . . . . . . . . hypercardioid
Radio
frequency range: . . . . 863 .125 – 864 .875 MHz
Audio
frequency range: . . . . 50 – 16 000 Hz
Frequency stability: . . ±0 .005 %
Transmitting power: . . < 10 mW (EIRP)
Ambient temperature: 0 – 40 °C
Power supply: . . . . . . two 1 .5 V batteries
Dimensions: . . . . . . . . ⌀ 50 mm × 260 mm
Weight: . . . . . . . . . . . 350 g
Subject to technical modification .
All rights reserved by MONACOR
GmbH & Co. KG. No part of this instruction manual
may be reproduced in any form or by any means for
any commercial use.
microphone with
PLL multifrequency
transmitter
size AA (R6)
INTERNATIONAL
®
9