Automatic Circuit Identifier
with Analog Receiver
The task of locating AC circuits is now made quick and easy. No more
guessing or trial and error when it comes to locating the correct circuit
breaker supplying power to an AC outlet or lighting fixture.
WARNING:
Use extreme care when working around AC circuits, severe shock hazards exist.
If used on a circuit controlled by a dimmer, turn the dimmer to the highest on
position. Do not use in cardiac care areas.
Features:
• Automatically and quickly finds correct breaker
• Transmitter works on 120VAC
• Verifies presence of power
Locating A Circuit Breaker or Fuse:
1. Plug the transmitter into the receptacle.
2. Go to the circuit breaker panel box.
3. Turn the receiver on.
4. Place the flat surface of the tapered end of the receiver directly onto the circuit
breaker or fuse as shown. If the receiver is held at any other angle, inaccurate
readings may occur.
5. Slide the nose of the receiver down each breaker along both sides of the panel. Note
that the receiver will beep frequently as it measures the relative signal strength.
6. Move the receiver down each breaker once more. On the second pass, the receiver
will beep and the red LED will light only at the circuit breaker powering
the transmitter.
7. Trip the breaker off and check that the LED on the transmitter in the outlet is off
to confirm you have found the correct breaker or fuse.
Locating a Circuit Breaker or Fuse Controlling an Incandescent Light Fixture
1. If the incandescent light fixture is controlled by a wall switch, make sure the wall switch is OFF.
2. Remove light bulb.
3. Install a Screw-in socket adapter (not included).
4. Plug the transmitter into the adapter.
5. Turn on the wall switch and follow the procedure described in Locating a Circuit Breaker or Fuse, steps 3
through 7.
Battery Replacement:
Unscrew and remove battery cover. Insert new 9V battery into battery compartment and re-install battery cover.
Clean with a dry cloth.
Specifications:
Operating Voltage: 100-140VAC
Operating Frequency: 47-63Hz
Maximum Load: 18A (4ms) at 120VAC, 200mW max, at 120VAC
Duty Cycle: Max: 4mS every 16.6mS (continuous), (.24%)
Weight (excluding battery): Transmitter approx 50gr., Receiver approx. 85 gr.
Power Supply: 9VDC battery
Operating Storage Temperature: 0 to 50ºC
Power Switch
LED
LED
Battery Compartment
N12966
#61-532

Publicidad

loading

Resumen de contenidos para Ideal 61-532

  • Página 1 #61-532 Automatic Circuit Identifier with Analog Receiver The task of locating AC circuits is now made quick and easy. No more guessing or trial and error when it comes to locating the correct circuit breaker supplying power to an AC outlet or lighting fixture.
  • Página 2: Warranty Statement

    Any implied warranties arising out of the sale of an IDEAL product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. The manufacturer shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss.
  • Página 3: Identificador Automático De Circuitos Con Receptor Analógico

    #61-532 Identificador automático de circuitos con receptor analógico La tarea de localizar circuitos de CA es ahora rápida y sencilla. No más adivinación ni prueba y error cuando se trata de localizar el disyuntor correcto que suministra alimentación a un tomacorriente o artefacto luminoso.
  • Página 4: Disposición Final De Desechos De Equipos Eléctricos Y Electrónicos

    Se garantiza este instrumento al comprador original contra defectos de material o mano de obra por dos años contados a partir de la fecha de compra. Durante este período de garantía, IDEAL INDUSTRIES, INC. podrá, a la sola opción de IDEAL, reemplazar o reparar la unidad defectuosa, sujeto a verificación del defecto o falla.
  • Página 5 #61-532 Identificateur automatique de circuit à récepteur analogique Le repérage des circuits c.a. est désormais plus rapide et plus facile. Plus d’incertitude et de tâtonnements pour localiser le disjoncteur correspondent à une prise ou un appareil d’éclairage c.a. donné. AVERTISSEMENT : Procéder avec une prudence extrême quand on travaille sur des circuits c.a., il...
  • Página 6: Déclaration De Garantie

    Toutes les garanties implicites résultant de la vente d’un produit IDEAL, incluant sans y être limitées les garanties implicites de valeur marchande et d’adaptation à une fin particulière, sont limitées aux conditions ci-dessus. Le fabricant ne sera pas tenu pour responsable de la perte d’usage de l’instrument, ni d’autres dommages accessoires ou indirects, dépenses ou préjudice...