Installation Instructions
Cutout for 30"
A
only Under Counter
For JTP30, JTP70, PT916, PT920, ZET938 models only.
Gas or electric cooktops may be installed over this oven. See
cooktop installation instructions for cutout size. See label on
top of oven for approved cooktop models.
25" (63.5 cm)
Top and/or side fillers
may be necessary
if unit is positioned
between existing
cabinets. Be sure
they are attached
securely, since they
will anchor the oven
in the cabinet.
3/4" (1.9 cm)
Support Platform
Required
MUST SUPPORT 150 LBS. (68 Kg)
Side by Side Installations
Install two wall ovens in separate cutouts.
Allow 2" (5.1 cm) min. between cutouts.
(76.2 cm)
28 1/2" (72.4 cm) Min.
28 5/8" (72.7 cm) Max.
27 1/4" (69.2 cm) Min.
27 5/16" (69.4 cm) Max.
11
Single Built-In Ovens
240V / 208V
Junction Box
Location (junction
box may be in
adjacent cabinet)
9 1/2"
(24.1 cm)
Max.
Allow 1" (2.5 cm)
overlap top
of oven,
11/16" (1.8 cm)
overlap side edges
of cutout and
1 1/4" (3.2 cm)
overlap bottom
of oven.
Must
match
NOTE: This oven is only
toekick
approved to be installed under
height
the specific models as labeled
on this unit.
2" (5.1 cm)
Cutout –
Min.
Observe all
dimensions
dimensions
and
requirements.
requirements.
Gas and electrical connections
for gas cooktop must be located
in an adjacent accessible
location to the right.
36" (91.4 cm)
22" (55.9 cm) Min.
Typical
Above Support
Countertop
Platform
Height
24" (61 cm)
4" (10.2 cm)
Typical
Toekick
Cutout –
Observe all
and

Publicidad