Forch BT-D 6-12 V Manual Del Usuario página 19

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
SYSTEM TEST
Press «ENTER» button to proceed the test for regular starting battery.
Press the ◄ ► key to select battery type:
a. REGULAR FLOODED
b. AGM FLAT PLATE
c. AGM SPIRAL
d. VRLA/GEL
Press «ENTER» to confirm choice.
Press the ◄ ► key to select the battery rating:
SAE (CCA), EN, IEC, DIN or JIS.
Press «ENTER» to confirm choice.
Press the ◄ ► key to input the battery capacity:
SAE (CCA): 40~2,000
EN: 40~2,100
DIN: 25~1,300
IEC: 30~1,500
JIS: Battery Type No.
Press «ENTER» to begin test.
Press the ◄ ► key to confirm the position of the battery if the surface charge is de-
tected. Follow the tester 's steps to remove the surface charge if it happens. Then testing
proceeds.
When test is completed, the display shows the results as following {Press the◄ ►key to
select: SOH (STATE OF HEALTH) or SOC (STATE OF CHARGE)}.
GOOD & PASS
The battery is good & capable of holding a charge.
GOOD & RECHARGE
The battery is good but needs to be recharged.
RECHARGE & RETEST
Battery is discharged, the battery condition cannot be determined until it is fully charged.
Recharge & retest the battery.
BAD & REPLACE
The battery will not hold a charge. It should be replaced immediately.
BAD CELL & REPLACE
The battery has at least one cell short circuit. It should be replaced immediately.
End of test. Precede the printout if needed.
NOTE that there might be some messages displayed to different circumstances as below.
LOAD ERROR
The tested battery is bigger than 2000SAE (CCA). Or the connection is not properly
established. Check the capacity of the battery & make sure the clamp lead is properly
connected.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

5439 105

Tabla de contenido