Eq Profiles; Infra Red Remote Codes; Rs232; Rs232 Wiring Configuration - Monitor Audio GOLD W12 El Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68

EQ Profiles

Impact: Uses the maximum natural efficiency of the
drivers for explosive impact.
Flat: This is the sweet spot between a flat extended
response and minimal use of DSP enhancement. A
good starting point to create your own custom EQ
profiles from.
Movie: The same flat response with good
sensitivity, but a little more extension to create a
balance between the explosive and atmospheric
moments of a good film.
Music: Maximum low frequency extension to pick
out the fundamental frequencies of every musical
instrument.

Infra Red Remote Codes

The Gold W12 has discreet remote control
commands for use with universal remote controls,
along with additional commands not found on
the supplied remote. The commands follow the
standard NEC protocol.
Device Address: 7D28
POWER 48
ON
D1
OFF
F1
MUTE
78
VOL_UP A0
VOL_DOWN
08
PRESET_1
28
PRESET_2
58
PRESET_3
88
PRESET_4
B8
TOGGLE_SOURCE 00
VOLUME_SELECT 28
LPF_SELECT
A8
PHASE_SELECT
D8
DISPLAY 30
ENCODER
D0
PRESET_SELECT
B8
RIGHT_BUTTON
E0
LEFT_BUTTON
C0
PLAY_PAUSE
D8
TOGGLE_NIGHTMODE
A8
NIGHTMODE_ON
D2
NIGHTMODE_OFF F2
ROOMEQ_ON
D3
ROOMEQ_OFF
F3
DISPLAY_ON
D4
DISPLAY_OFF
F4
monitoraudio.com

RS232

The Gold W12 can be controlled via the RS232
port on the amplifier panel. The Gold W12 can be
controlled by sending a string of characters to the
RS232 connector.

RS232 Wiring Configuration

The RS232 communication socket uses a standard
RJ45 connector. This should be wired as illustrated
on the amp panel and below.
1 2
3
4
5
6
RS232 Communication Set-Up
Parameters
Baud Rate: 57600
Data Size: 8
Parity: None
Stop Bits: 1
Handshaking/ Flow Control: None

Command Protocol

Each string of commands sent to the Gold
W12 must follow the same structural protocol.
These commands are detailed in the Command
List opposite. To control the Gold W12 using
RS232 commands, specific strings of characters
(forming a command string) must be sent via a
RS232 terminal. Each command string should be
terminated by both:
<CR> (the ASCII carriage return character, 13 decimal)
<LF> (the ASCII line feed character, 10 decimal)
These are generally found in the RS232 terminal
settings. The Gold W12 replies to a valid
command with the updated information changed
by a SET command, or the information that was
requested by a GET command. If the Gold W12
receives an invalid command it will reply with
ERROR<CR><LF>
Note: any SET command other than SET_O during
Standby is deemed invalid.
1.
Not Used
2.
Not Used
3.
Ground
4.
Ground
5.
Rx
6.
Tx
7.
Not used
8.
Not Used
7
8
10

Publicidad

Tabla de contenido
loading

Tabla de contenido