The selected setting is displayed on the digital readout. The higher the setting, the
faster water is evaporated and released into the air. F1 (LOW) is the quietest
setting and is provided for conditions that do not require a rapid evaporation rate.
Humidity Control
This button allows you to adjust the humidity to suit
your needs. This humidifier will automatically cycle
on and off as required to maintain the selected
setting.
The readout displays both actual (ROOM) and
desired (SET) humidity percentage (%) settings
when humidity control button is pressed. The ROOM readout has a range of 20%
to 95% RH. If the room humidity level is equal to or less than 20% RH the display
will show a flashing 20.
The SET readout has a range of 25% to 65% RH and is adjusted in increments of
5%. Initially depressing the humidity button will display the current humidity setting.
Each additional press of the button increases the setting by 5%. A SET point of
65% RH operates the humidifier continuously regardless of the ROOM reading.
The humidistat that senses the readings is located on the power cord. Insure that it
is free from obstruction.
Refill Display
For maximum run time both the bottle and the base should
be filled. When both the bottle and the base are empty, the
display alternates the room humidity reading and "F"
(FILL), indicating additional water is required.
Check Filter Indicator
The ability of any humidifier to efficiently supply humidity
output relies heavily on the condition of the filter. As the
filter loads with impurities it gradually loses its wicking
capability. When this happens, moisture output is
reduced and the humidifier has to work longer to satisfy
the selected setting. This humidifier has a check filter
reminder timed to appear after 720 hours of operation.
When the display shows an alternating "CF" and "room
humidity" setting at 5 second intervals it is a reminder to check the filter condition.
NOTE: Some areas have high water mineral content causing the need for more
frequent filter changes.
Reset the Check Filter "CF" function each time you replace a filter by unplugging
the unit from the power source for 1-2 minutes, then plug it in again.
Refer to "Replacement and Care of Filter" section below. If a build-up of deposits
or severe discoloration is evident, replace the filter to restore maximum efficiency.
Control Lock Feature
To avoid unwanted tampering with the humidifier settings the controls can be
locked.
Activation Procedure
After the humidifier functions have been set up, hold
the power button down for 5 seconds. The display will
show "CL" for 2 seconds; release the power button
and the control will resume the display of the room
humidity. The humidifier will continue to function with the locked in settings. If
buttons are operated while "CL" is active, the "CL" is displayed and settings are
unaffected.
8