63
EN
INSTAllATION GUIDE FOR HARmONICS AND FlICKER
INSTALLATION GUIDE FOR HARMONICS AND FLICKER
※ The below installation guide is limited applicable only for model
Model : Rv1329CN1T, Rv1329CN4T, Rv1329CN7T, Rv1329C1T, Rv1329C4T,
Rv1329C7T
Installation Guide for harmonics (EN 61000-3-2 & EN 61000-3-12)
This equipment complies with IEC (EN) 61000-3-12 in harmonic currents emission limits corresponding Rsce=33.
Installation Guide for Flicker (EN 61000-3-3 & EN 61000-3-11)
This device is intended for the connection to a power supply system with a maximum permissible system impedance
Zmax of 0.3996(0.339+j0.212)Ω at the interface point (power service box) of the user's supply. The user has to ensure
that this device is connected only to a power supply system which fulfills the requirement above. If neccessary, the
user can ask the public power supply company for the system impedance at the interface point.