Screw the non return valve with seals (27) to the
G 3/8" water supply pipe. Connect the flexible
pipe with the G 3/8" cap to the fitting with the non
return valve (27). Screw the T-shaped fitting (26)
to the G 3/8" thread boiler outlet (colour red)
making sure the washer is positioned correctly.
Screw the flexible pipe of the shower head (10) to
the T-shaped fitting (26) placing the washer in the
correct position. Connect the blue flexible pipe
to the boiler inlet (colour blue) and the red flexible
pipe to the T-shaped fitting (26).
BLANCOORION-F ND
Connect the blue flexible pipe to the boiler inlet
(colour blue) and the red flexible pipe to the boiler
outlet (colour red).
2
4
Connections
A.
Cold water inlet pipe
B.
Heating boiler inlet pipe ( blue colour)
C.
Hot water from heating boiler (red colour)
Functioning
Open the lever in hot water position and wait
for the water outlet, then join the battery to the
electricity. Switching on the battery ignition before
of the water refilling cause the fuse breaking inside
of the boiler.
Remarks
Switching on the heating boiler the increasing
volume of the water can cause a leakage of the
mixer. This is a normal and necessary appearance.
The container of the water must not be under
pressure and particularly on the spout you must
not use aerators or connections different from the
one supplied. The mixer BLANCOORION-S-F ND
is normally equipped with non-return valves
according to the DIN-DVGW to be fitted to the
supplying water pipe.
Important information
• Do not kink the flexi-hoses
• Do not strain the flexi-hoses
• Only screw the flexi-hoses manually into the
body of the fitting.
• When connecting the flexi-hoses to the angle
valves, they must be held firmly to prevent the
hoses becoming twisted or detached from the
body of the fitting.
Maintanance
Jet regulator
1. Loosen jet regulator (8)
2. Flush jet regulator sieve under flowing water
3. Reinsert jet regulator
Replacing the cartridge
1. Shut off cold and hot water supply at the angle
valve
2. Loosen coloured cap (2) and the holding
screw (3) of the lever (1)
3. Remove lever
4. Remove the cartridge lock nut (5)
5. Remove cartridge (6) and replace
6. Assemble in reverse order
Care
In order that your BLANCO kitchen fitting will pro-
vide you with years of pleasure, we recommend
it is cleaned by wiping regularly with a soft cloth
(BLANCO microfibre cloth is recommended). Use
clean water or a mild cleaning agent.
On no account should abrasive (neither liquid nor
powder) cleaning agents or those containing alco-
hol or acid-based or other "aggressive" agents be
used. Scouring sponges are equally unsuitable.
The use of proscribed cleaning agents can dama-
ge the finish. Such damage is not covered by the
guarantee.
Guarantee
If a claim is made on the guarantee, the claimant
must produce the invoice on which the date of
purchase or installation is stated.
We reserve the right to make technical changes.