Página 1
Owner’s Manual Models: H, K Plus Models: H Plus, K Plus PRO Models: PRO10, PRO20, PRO30, PRO50 Powered by 425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1 t. (+1) 519.763.1032 • f. (+1) 800.265.7246 (US and Canada only) t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069 e-mail: info@viqua.com...
Página 2
• VIQUA replacement lamps undergo rigorous performance testing and strict quality control processes to ensure that the safety and performance certifications of the original equipment are not compromised. So, you can see that it's simply not worth the risk! Insist on genuine VIQUA replacement lamps.
Safety Information Section 1 Safety Information Please read this entire manual before operating this equipment. Pay attention to all danger, warning, and caution statements in this manual. Failure to do so could result in serious personal injury or damage to the equipment. Make sure that the protection provided by this equipment is not impaired.
Safety Information WA R N I N G During extended periods of no water flow, the water in your chamber can become very hot (Approx. 60 °C) and potentially lead to scalding. It is recommended to run your water until this hot water has been purged from your chamber. Do not allow water to contact your skin during this time. To eliminate this condition, a temperature management valve can be installed at the outlet of your UV system.
K Plus 650709-004 660018-R Top Bolt and Wireform 602916 & 602896 Used for all systems 602854 PRO10 Lamp 602855 PRO20, H Plus, H 602856 PRO30/50, K Plus, K 602974 PRO10 Sleeve 602975 PRO20, H Plus, H 602976 PRO30/50, K Plus, K...
Página 6
General Information Bottom bolt (includes screw) 603053 Used for all systems Sleeve Removal Tool 602988 Used for all systems 410982R-10 PRO10 Flow Meter Sensor (PRO models only) 410982R-20 PRO20 410982R-30 PRO30 Sensor 650580 PRO and Plus models Plug Basic models 602636 110V - Used for all systems Power cord...
Página 8
Note: DO NOT use wrench to positive stop. • PRO10: 18.5" Note: LED must face up. • H, PRO20: 27.5" Ensure proper length of straight pipe 1.0" Diameter at • K, PRO30/50: 37.5" inlet side of Flow Meter Note: Ensure chamber is Sensor and use a 1¼”...
Página 9
Installation 4¹⁄16“ (10.4cm) • Wet O-ring with water then • Install and rotate the lamp • Install the controller unit to • Connect UV sensor into blue place over bottom end of into the sleeve assembly. the wall. Ensure that the jack (For PRO and Plus sleeve.
Página 10
Installation Procedure: • Disconnect the controller then • Shut off the water supply. • Press the pressure button to • Remove filter housing(s) disconnect the UV sensor release the pressure from the using sump wrench. • Open an upstream faucet to from blue jack.
Página 11
Maintenance Section 4 Maintenance WA R N I N G • Always disconnect power before performing any work on the disinfection system. • Always shut-off water flow and release water pressure before servicing. • Regularly inspect your disinfection system to ensure that the power indicators are on and no alarms are present. •...
Página 12
Maintenance Commercial Scale Remover • Restore Power. • Remove the UV sensor from • Lock the wire form into • Turn on the water supply. the unit. position. • Press and hold the “New Lamp” button for 5 seconds • Submerge end of the sensor till you hear a beep.
Página 13
Maintenance Procedure: • Remove the sleeve bolt from • Remove screw from the • Insert the sleeve removal tool • Pry sleeve upward until it top of the sleeve assembly. sleeve bolt. into the bottom of the sleeve. come loose. •...
Maintenance • Reinstall the O-ring at the • Connect the sleeve bolt at the bottom of the sleeve. bottom. • When service is complete, assemble the prerequisites in the reverse order of disassembly. Note: After replacing the UV lamp or sleeve perform the disinfection procedure, refer to Section 3.2.
Operation Section 5 Operation 5.1 Control Panel Figure 3 Control Panel Buttons and Display Feature Description Function Press to silence audible alarm. When the alarm is due to the lamp's age, the mute button will silence the audible alarm for 7 days; this Mute may be repeated up to a maximum of 4 times.
Troubleshooting Section 6 Troubleshooting Symptom Possible Cause Possible Solution Reset GFCI and/or breaker GFCI and/or breaker tripped Replace controller fuse - see Fuse Replacement section Controller fuse has blown (Refer Section 4.3). No power Transient voltage surge suppressor (TVSS) damaged Replace TVSS Controller damaged Replace controller and use a TVSS...
Página 17
2 years * PRO50 has a minimum UVT rating of 85% PRO10 PRO20 PRO30 PRO50 H, H Plus K, K Plus 30 gpm (113 lpm) 10 gpm (38 lpm) 20 gpm (76 lpm) Rated flow for NSF Std 55, Class A (2.2 m...
Página 18
Specifications PRO Series Plus Series Basic Series Sensor CoolTouch fan Dynamic flow restrictor Yes (Except PRO50) Communications ports (two, RJ45) COMMcenter control package Optional Optional Optional Solenoid valve Optional Optional Optional Flow Meter Sensor (PRO10, 20, 30 Models only) Controls Audible alarm mute button New lamp button Lamp age indicator...
Página 19
VIQUA warrants the electrical (controller) and hardware components to be free from defects in material and workmanship for a period of five (5) years from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts covered by the warranty.
Página 20
(+1) 519.763.1032 • f. (+1) 800.265.7246 (solo EE. UU. y Canadá) t. (+31) 73 747 0144 (Europe seulement) • f. (+1) 519.763.5069 t. (+31) 73 747 0144 (solo Europa) • f. (+1) 519.763.5069 Courriel : info@viqua.com correo electrónico: info@viqua.com www.viqua.com...